Adjustment facilities on the Phono module MC

Switch positions
Setting the input
sensitivity
(Gain)
Input sensitivity
Note: 1000 µV corresponds to 1 mV
Downloaded from
www.Manualslib.com
1L
2L
Miniature switches „1" are used to set the desired input sensitivity for the
left (1L) and right (1R) channels as shown in Table 3.
The information you need for this will be included in the manufacturer's
specification for the pick-up system you intend to use. Select the value
which is closest to the manufacturer's stated figure. It is essential to set
the same value for both channels.
If you do not have access to the manufacturer's specification, a good
starting point for sensitivity is 500 µV. This is the factory default setting.
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
ON
OFF
ON
ON
ON
ON
manuals search engine
1R
2R
OFF
OFF
1200 V
OFF
ON
ON
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
OFF
OFF
ON
ON
20
Input sensitivity [V]
2000 V
>
2000 V
...
800 V
1200 V
...
600 V
800 V
...
400 V
600 V
...
300 V
400 V
...
200 V
300 V
...
160 V
200 V
...
100 V
160 V
...
Table 3