Prepare the appliance for first use.
3.
→ Page 115
Electrically connect the appliance.
4.
→ Page 116
Criteria for the installation loca-
tion
Follow these instructions when in-
stalling your appliance.
WARNING
Risk of explosion!
If the appliance is in a space that is
too small, a leak in the refrigeration
circuit may result in a flammable mix-
ture of gas and air.
Only install the appliance in a
space with a volume of at least
3
1 m
per 8 g refrigerant. The
volume of refrigerant is indicated
on the rating plate. → Fig. 
The weight of the appliance ex works
may be up to 70 kg depending on
the model.
The subfloor must be of sufficient sta-
bility to bear the weight of the appli-
ance.
Permitted room temperature
The permitted room temperature de-
pends on the appliance's climate
class.
The climate class can be found on
the rating plate. → Fig. 
Climate class Permitted room temperat-
ure
SN
10 °C to 32 °C
N
16 °C to 32 °C
ST
16 °C to 38 °C
T
16 °C to 43 °C
The appliance is fully functional within
the permitted room temperature.
/
1
4
/
1
4
Installation and connection en
If an appliance with climate class SN
is operated at colder room temperat-
ures, the appliance will not be dam-
aged up to a room temperature of
5 °C.
Niche dimensions
Observe the niche dimensions if you
install your appliance in the furniture
recess. If this is not the case, prob-
lems may occur when installing the
appliance.
Niche depth
Install the appliance in the recom-
mended niche depth of 560 mm.
If the niche depth is smaller, the en-
ergy consumption increases slightly.
The niche depth must be a minimum
550 mm.
Niche width
An inside niche width of at least
560 mm is required for the appli-
ance.
Side-by-side installation
If, in addition to this appliance, you
want to operate another appliance
featuring a freezer compartment, you
must maintain a distance of at least
150 mm between the appliances.
If you do not observe the minimum
distance, you can only set up this ap-
pliance next to 556 mm wide appli-
ances without a freezer compartment.
Preparing the appliance for the
first time
Remove the informative material.
1.
Remove the protective foil and
2.
transit bolts, e.g. remove the ad-
hesive strips and carton.
Clean the appliance for the first
3.
time. → Page 122
115