Results of the
Previous Firing
Error Messages
manuals search engine
After the firing is completed the follwing results of the
firing can be displayed in (1) by keeping the key (7)
pressed:
• operation hours of the heating elements
(net time) since starting the firing
• total operation hours of the heating elements
(net time) since using the controller
• temperature at the end of the firing resp. when
error occured
• elapsed time since end of firing resp. when
error occured
The integrated microprocessor inside your PYROTEC
D1 performs continuous checking of the firing
process. In case of any malfunction the display reads
an error message pointing to the problem. Following is
a description of the possible error messages:
The kiln doesn´t follow the required temperature
increase. This error message points clearly to a kiln
problem. Possible cause:
• broken fuse, power phase or relay failed
• the door (lid) contact is open
• a heating element is broken
• the heating elements are too old
(esp.with high firing temperatures)
• the thermocouple has a short circuit
Safety Switch Off feature was activated
The PYROTEC D1 has detected an overtemperature in
the kiln and switched off the kiln by the 2nd power
relay (20°C overshoot vs. T1 or T2 at or above 900°C).
Check and repair the cause carefully before continue
using the kiln again to avoid further damage !