People Counter RAZL-2CO (Translation)

2.20 Technical specifications

230 V AC
Connector
over 4 m long connection cable with safety plug
Switching output
Potential-free, 1 changeover contact via 4 m long connection cable
(optional)
max. 250V AC / max. 12A / max 3000 VA
Reflector pillar: 119,8 cm
Pillar height
Sensor pillar: 130 cm
Pillar width
9 cm without stand
Pillar depth
8,5 cm without stand
Stand
20 cm diameter
Reflector pillar: approx. 6.7 kg
Weight
Sensor pillar: approx. 7.5 kg
Maximum distance
2 m
between the pillars
Operational readiness
after < 95 seconds
Configuration via
The sensor pillar provides a WLAN for mobile devices with web browser such as smartphone, tablet or notebook for con-
WLAN
figuration
Fiessler Elektronik GmbH & Co. KG
Buchenteich 14, D-73773 Aichwald
-31-
Phone: +49 (0)711 - 91 96 97 - 0
Fax: +49 (0) 711 - 91 96 97 - 50
04.06.2020
Internet: http://fiessler.de
E-Mail: info@fiessler.de