ACTIVE P30 Plus Series Owner's Manual

Specifications

System performance
Power Source
Dimensions (w/o cuff )
Weight (w/o cuff )
Cuff Size
Memory
Power Saving
System Operating Conditions
Device Storage/Transport
Conditions
Power Supply Input
Blood pressure measurement performance
Measurement unit
Systolic Measurement Range
Diastolic Measurement Range
Pulse Rate Measurement
Range
Accuracy of Pressure
Accuracy of Pulse Rate
This device has been tested to meet the electrical and safety
requirements of: IEC/EN 60601-1, IEC/EN 60601-1-2.
Four 1.5V AA alkaline batteries
150 (L) x 100 mm (W) x 70.5 mm
(H)
400g with batteries
24-43 cm (9.4 - 16.9 inches) with
air tube 100 cm
Maximum 200 memory records
(P30 Plus BT); 60 (P30 Plus)
Automatic power off if system is
idle for 3 minutes
10°C to 40°C (50°F to 104°F), below
85% RH
-20°C to 60°C (-4°F to 140°F), below
95% RH
DC +6V / 1A (max) via Power Plug
mmHg
50 mmHg -255 mmHg
25 mmHg -195 mmHg
40 -199 beats / minute
±3 mmHg or ±2% of reading
±4% of reading
Reference to Standards:
• EN 1060-1 /-3, NIBP-requirements
• IEC60601-1 General requirement for safety
• IEC60601-1-2 Requirements for EMC
• EN1060-4, NIBP clinical investigation
• AAMI/ANSI /IEC 80601-2-30, ANSI/AAMI/ISO 81060-2, NIBP
requirements

WARRANTY TERMS AND CONDITIONS

With respect to disposable products, ForaCare Suisse warrants
to the original purchaser that, at time of delivery, each standard
product manufactured by ForaCare Suisse shall be free of defects
in material and workmanship and, when used for the purposes
and indications described on the labeling, is fit for the purposes
and indications described on the labeling. All warranties for a
product shall expire as of the product expiration date, or if none,
after one (1) year from the date of shipment from ForaCare
Suisse. ForaCare Suisse warranty hereunder shall not apply if: (i)
a product is not used in accordance with its instructions or if it is
used for a purpose not indicated on the labeling; (ii) any repairs,
alterations or other work has been performed by Buyer or
others on such item, other than work performed with ForaCare
Suisse's authorisation and according to its approved procedures;
or (iii) the alleged defect is a result of abuse, misuse, improper
maintenance, accident or the negligence of any party other than
ForaCare Suisse. The warranty set forth herein is conditioned
upon proper storage, installation, use and maintenance in
accordance with applicable written recommendations of
ForaCare Suisse. The warranty furnished hereunder does not
extend to damage to items purchased hereunder resulting in
whole or in part from the use of components, accessories, parts
or supplies not furnished by ForaCare Suisse.
EN-10