Herunterladen Inhalt Inhalt Diese Seite drucken

Important Remarks; Important Safety Instructions; Installation Instructions - Riello Elettronica Cardin BL Serie Installationsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 31

IMPORTANT REMARKS

READ THE FOLLOWING REMARKS CAREFULLY BEFORE PROCEEDING WITH THE INSTALLA-
TION. PAY PARTICULAR ATTENTION TO ALL THE PARAGRAPHS MARKED WITH THE SYMBOL
NOT READING THESE IMPORTANT INSTRUCTIONS COULD COMPROMISE THE CORRECT WORK-
ING ORDER OF THE SYSTEM AND CREATE DANGER SITUATIONS FOR THE USERS OF THE SYSTEM.
• These instructions are aimed at professionally qualified "installers of electrical equip-
ment" and must respect the local standards and regulations in force. All materials used
must be approved and must suit the environment in which the installation is situated.
• All maintenance operations must be carried out by professionally qualified technicians.
Before carrying out any cleaning or maintenance operations make sure the power is
disconnected at the mains.
• This appliance must be used exclusively for the purpose for which it has been made.
"i.e. for the automation of hinged gates" with one or two gate leaves.
• The unit may be fitted both to the right and to the left of the passageway.
This product and all its relative components has been designed and manufactured by
Cardin Elettronica who have verified that the product conforms in every aspect to the
safety standards in force.
Any non authorised modifications are to be considered improper dangerous and the
complete responsibility of the installer.
Caution! Mechanical stop buffers must be installed in both the closing and
opening positions. (pos. 1, 2 and 3, fig. 5).

IMPORTANT SAFETY INSTRUCTIONS

It is the responsibility of the installer to make sure that the following public safety condi-
tions are satisfied:
1) Ensure that the gate operating installation is far enough away from the main road to
eliminate possible traffic disruptions.
2) The motor must be installed on the inside of the property at a height between 1,5 and
1,8 m and not on the public side of the gate. The gates must not open onto a public
area.
3) The gate operator is designed for use on gates through which vehicles are passing.
Pedestrians should use a separate entrance.
4) The gate must be in full view when it is operating therefore controls must be situated
in a position where the operator can see the gate at all times.
5) At least two warning signs (similar to the example on the right) should
be placed, where they can be easily seen by the public, in the area of
the system of automatic operation. One inside the property and one
on the public side of the installation. These signs must be indelible
and not hidden by any objects (such as tree branches, decorative
fencing etc.).
6) Make sure that the end-user is aware that children and/or pets must
not be allowed to play within the area of a gate installation. If possible
include this in the warning signs.
7) Whenever a fully open gate leaf comes within at 500 mm of a fixed structure the space
must be protected by an anticrush buffer.
8) You are advised to protect the system's lateral access points with pairs of (FS) photocells
connected to the stop input, see installation example, component 14 on page 2.
9) If you have any questions about the safety of the gate operating system, do not install
the operator. Contact your dealer for assistance.
TECHNICAL DESCRIPTION
200/BLEGOS Self-locking electromechanical 24 Vdc ram suitable for hinged gates up
to 2,5 m in length and 200 kg in weight (per gate leaf).
200/BLESOL Self-locking electromechanical 24 Vdc ram suitable for hinged gates up
to 3,5 m in length and 300 kg in weight per gate leaf (up to 4 m, 300 kg addition of an
electric locking device).
• Drive motor maximum 28 Vdc with an incorporated encoder
• Self-locking geared motor with a watertight container in extruded aluminium containing
cyclic train gears. Rotation is supported by a system of double bearings.
• The release mechanism that guarantees emergency manoeuvring is extremely efficient
under all working conditions and is protected by a solid shock-proof plastic carter with
a key lock.
• The terminal board (wired up using Cardin cable CABPC10) is located in a special
compartment fitted with a cable clamp and a protective cover.
• The covering components are finished in spray painted aluminium.
• Brackets and accessories in zinc-plated steel.
ACCESSORIES
980/XLSE11C - Electric locking device 12 Vac/dc
IMPORTANT REMARKS
USER INSTRUCTIONS
Attention! Only for EU customers - WEEE marking.
This symbol indicates that once the products life-span has expired it
must be disposed of separately from other rubbish. The user is therefore
obliged to either take the product to a suitable differential collection site for
electronic and electrical goods or to send it back to the manufacturer if the
intention is to replace it with a new equivalent version of the same product.
Suitable differential collection, environmental friendly treatment and disposal contrib-
utes to avoiding negative effects on the ambient and consequently health as well as
favouring the recycling of materials. Illicitly disposing of this product by the owner is
punishable by law and will be dealt with according to the laws and standards of the
individual member nation.
During the opening/closing manoeuvre check for correct operation and activate the
emergency stop button in case of danger. During blackouts the gate can be released
and manually manoeuvred using the supplied release key (see manual release page
4). Periodically check the moving parts for wear and tear and grease if required,
paying particular attention to the never ending screw pos. 7 fig. 2, using lubricants
which maintain their friction levels unaltered throughout time and are suitable for
temperatures of -20 to +70°C.
Periodically check the correct operation of all safety devices (photoelectric cells etc.).
Eventual repair work must be carried out by specialised personnel using original spare
parts. The appliance is not suitable for continuous operation and must be adjusted
according to the model (see technical data on page 48).

INSTALLATION INSTRUCTIONS

The minimum controls which may be installed are OPEN-STOP-CLOSE, these
controls must be installed in a location not accessible to children and outside the
opening range of the gate.
Before starting the installation of the system check that the structure which is to be
WARNING
automated is in good working order and respects the local standards and regulations
AUTOMATIC OPENING
KEEP CLEAR
in force. To this end make sure that the gate is sufficiently rigid (if necessary reinforce
the structure) and that it pivots easily.
You are advised to grease all the moving parts using lubricants which maintain unal-
tered friction characteristics over a period of time and are suitable for temperatures
of -20 to +70°C.
CHILDREN OR PETS MUST NOT
BE ALLOWED TO PLAY ON OR
NEAR THE INSTALLATION
• Check the safety measures between the fixed and moving parts:
- a minimum space of 30 mm must always be left along the entire distance
between the gate and the support column measured throughout the entire
opening angle of the gate.
- make sure that the space between the bottom of the gate and the pavement
never exceeds 30 mm throughout the entire opening angle of the gate.
• The surface of the gate must not feature openings which allow a person's hand
or foot to pass through.
• Check the exact positioning of the pivots, and their good working order (the upper
and lower hinges/pivots must be aligned on the same axis).
• Work out the run of the cables according to the command and control devices
fitted and make sure the system conforms to the local standard and regulations
in force (see installation example fig. 1 page 2).
• Check that the appliance is suitable for the size, weight and duty cycle of the gate
to which it is to be applied (see duty cycle on page 48).
ASSEMBLY PROCEDURE
The ram may be positioned to the right or to the left of the passageway.
• Move the gate/s to the closed position.
• Fasten the rear mooring bracket (supplied with a ferrule inserted) to the column
(fig. 7 page 5), taking into account the measurements "A" and "B", after having
checked the position of the gate hinge with respect to the column (measurement
"C" fig. 4 page 4) according to the type of opening required.
Note: if the gate brackets are to be pre-installed (front and rear) without the
presence of the ram, you must also consult the indications in figure 9.
• Slide off the worm screw protective cover (the screw, lead nut and adjustable
safety rings will now be exposed)
• Rotate the worm screw lead nut (part. 8 fig. 2) until it reaches 15 mm from the
end of the closing direction travel distance and rotate the mechanical travel
limits "5" and "9" along the screw to their optimum position.
15
IMPORTANT REMARKS

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis