1.
Intended Use of the
Sterisart
The new Sterisart
is a peristaltic pump equipped with
appropriate devices for attaching
a closed sterility test system and a
sample container.
The pump draws liquid from the
sample container into the specially
designed double tubing, distribut-
ing the liquid equally to both
sample containers of the sterility
test system. The sample is rinsed
in a similar way. After the nutrient
media is added, the sample
containers are incubated for a
prescribed time and evaluated.
Downloaded from
www.Manualslib.com
2.
®

Universal Pump

®
Universal pump
3.
manuals search engine
Important Notes on the Safe and Proper Usage of the
Sterisart
®
Universal Pump
®
– The Sterisart
Universal pump must
be switched off before any electrical
connections are made or broken
(e.g. when plugging in or unplug-
ging the power cable or foot
switch).
– The Sterisart
®
Universal pump
must only be used with the original
current-carrying parts supplied
with it (power cable with ferrite
core, D-Sub connecting cable and
foot switch). The D-Sub protective
cap supplied must cover the port
when the D-Sub connecting cable is
not connected.
– The Sterisart
®
Universal pump is
designed for use with Sterisart NF
filtration systems. The suitability of
any other tubing must be approved
by Sartorius Stedim Biotech.

Unpacking the Pump and Checking the Equipment Supplied

®
When unpacking the Sterisart
Universal pump 16419 make sure
not to leave any parts in the pack-
aging. The equipment supplied
includes the following accessories
(one of each):
– Sterisart
®
Universal pump 16419
– Power cable (depends on country
rating)
– Foot switch
– Ampoule breaker
– Container for draining
– Pump cover for container for
draining (Sterisart
®
units)
– Only authorized Sartorius Stedim
Biotech service technicians are
allowed to open the pump housing.
– Do not expose the Sterisart
®
Universal pump to extreme
temperatures.
– Improper use or handling will inval-
idate the manufacturer's guarantee.
– Sterisart
®
Universal pump may only
be used with a grounded, readily
accessible and fuse-protected
electrical outlet that complies with
national standards.
– Pump cover for container for
draining (Millipore units)
– Drain tubing
– Fastening arm
– Holding ring for bottles
– Support rod
– Bow
– Clamping lever with sleeve
– Operating instructions