Herunterladen Inhalt Inhalt Diese Seite drucken

Zeversolar Eversol serie Anleitung Seite 64

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

34
Resumabl
40
e Fault
1,2,3,4,
Permanen
8,9,10,
t Fault
11,39
Installation and operating instructions
•Check AC cable, grid connection on the inverter.
If this fault is still being shown, please call service.
•Check the grid voltage and grid connection on the inverter.
•Check the grid voltage at the point of connection of the inverter.
If the grid voltage is outside the permissible range due to local grid
conditions, try to modify the values of the monitored operational limits
after informing the electric utility company first.
•Check whether the airflow to the heat sink is obstructed.
•Check whether the ambient temperature around the inverter is too high.
Disconnect the inverter from the grid and the PV generator, reconnect
them after 3 minutes. If this fault is still being shown, please call service.
63

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis