Cable Design
The conductor cross-section should be dimensioned to avoid power loss in cables
exceeding 1% of rated output power.
The maximum cable lengths relative to the conductor cross-section as follows:
conductor
cross-section
4 mm²
6 mm²
8 mm²
conductor
cross-section
6 mm²
8 mm²
10 mm²
The required conductor cross-section depends on the inverter rating, ambient
temperature, routing method, cable type, cable losses, valid installation
requirements of the country of installation, etc.
Installation and operating instructions
Maximum cable length
Maximum cable length
TLC 15K
32 m
42.5 m
53 m
TLC 10K
32 m
48 m
64 m
TLC 17K
28 m
37.5 m
47 m
TLC 20K
24 m
32 m
40 m
21