Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Before Starting The Equipment - HERKULES DS 405 L Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Anleitung_DS_405_L_SPK7:_
GB
also observe the safety regulations, the assembly
instructions and the operating instructions to be found
in this manual.
All persons who use and service the equipment have
to be acquainted with this manual and must be
informed about the machine's potential hazards.
It is also imperative to observe the accident
prevention regulations in force in your area.
The same applies for the general rules of health and
safety at work.
The manufacturer will not be liable for any changes
made to the machine nor for any damage resulting
from such changes.
Even when the equipment is used as prescribed it is
still impossible to eliminate certain residual risk
factors. The following hazards may arise in
connection with the machine's construction and
design:
Harmful emissions of wood dust when used in
closed rooms.
Contact with the blade in the uncovered cutting
zone.
Injuries (cuts) when changing the blade.
Crushed fingers.
Kickback.
Tilting of the workpiece due to inadequate
support.
Touching the blade.
Catapulting of pieces of timber and workpieces.

4. Technical data

AC motor
230-240V ~ 50Hz
Power
70/120 Watt
Operating mode
S1/S2 5 min
Idle speed n
400-1500 min
0
Protection type
Stroke
Base area
470 x 190 mm
Tilting range of table
-45°/0°/45°
Size of table
420 x 270 mm
Length of saw blade
Max. cutting length at 90°
Max. cutting length at 45°
Weight
Wavelength of laser
Laser output
10
29.08.2008
14:47 Uhr
Load factor:
A load factor of S2 5 min (intermittent periodic duty)
means that you may operate the motor continuously
at its nominal power level (120 W) for no longer than
the time stipulated on the specifications label (5
minutes ON period). If you fail to observe this time
limit the motor will overheat. During the OFF period
the motor will cool again to its starting temperature.
Noise emission values
The sawʼs noise is measured in accordance with
DIN EN ISO 3744; 11/95, DIN EN 11201. The
machine may exceed 85 dB(A) at the workplace.
In this case, noise protection measures need to
be introduced for the user (ear-muffs).
Cutting
Sound pressure level L
82,6 dB
pA
Sound power level L
92,4 dB
WA
„The quoted values are emission values and not
necessarily reliable workplace values. Although there
is a correlation between emission and immission
levels it is impossible to draw any certain conclusions
as to the need for additional precautions. Factors
with a potential influence on the actual immission
level at the workplace include the duration of impact,
the type of room, and other sources of noise etc.,
e.g. the number of machines and other neighbouring
operations. Reliable workplace values may also vary
from country to country. With this information the
user should at least be able to make a better
assessment of the dangers and risks involved."

5. Before starting the equipment

-1
5.1 Please note
IP 20
All covers and safety devices have to be properly
15 mm
fitted before the machine is switched on.
It must be possible for the blade to run freely.
When working with wood that has been
processed before, watch out for foreign bodies
such as nails or screws etc.
127 mm
Before you actuate the On/Off switch, make sure
50 mm
that the saw blade is correctly fitted and that the
20 mm
machineʼs moving parts run smoothly.
17 kg
Before you connect the machine to the power
supply, make sure the data on the rating plate is
650 nm
the same as that for your mains.
< 1 mW
5.2 Mounting the saw on a workbench
1.
It is better to mount the saw on a solid wood
workbench rather than on a weak plywood stand
Seite 10
Idling
72,2 dB
81,8 dB

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis