Electrostatic Discharge - The components inside your Drobo and disk drives are sensitive to static electricity, also known
as electrostatic discharge. Before you install any disk drive, we recommend that you do the following: 1) Avoid static-
causing surfaces such as carpeted floors, plastic, and packing foam; 2) Discharge yourself by touching an unpainted metal
surface such as a desk or rack mount; 3) Remove disk drives from their antistatic bags only when you are ready to use
them. Be sure to follow any additional recommendations that the disk drive manufacturers provides.
Repair Technician Warning! - Before opening the DroboPro or DroboElite unit or removing the power supply assembly,
the AC cord MUST be unplugged from the outside of the unit and the unit must be unpowered. The System Earthing
connections of the internal AC cable must not be removed if the system is powered on for service access.
DroboPro Specifications & Systems Requirements – Power Supply: AC Input: 100/240 VAC, 1.8/0.75 A, 50/60 Hz;
Operating Temperature: 10°C-35°C (50°-95°F); Non-operating (storage): -10°-60°C (14°-140°F); Altitude (operating): 2,438
m (8,000 ft.); Operating Humidity: 5% - 80%; Dimensions: 12.17" wide x 5.46" tall x 14.1" long (309mm wide x 138.9mm
tall x 357.4mm long); Weight: 16 lbs 3 ozs.; Storage: Accepts up to eight 3.5" SATA I or II internal desktop hard drives;
Interfaces: USB 2.0, FireWire 800, and iSCSI; Drobo Dashboard Application (required for iSCSI): Microsoft® Windows®
Operating Systems, Apple® Macintosh® OS-X v10.4+ (10.5.6+ required for iSCSI); File system support: NTFS, HFS+, FAT32,
and EXT3.
DroboElite Specifications & Systems Requirements – Power Supply: AC Input: 100/240 VAC, 1.8/0.75 A, 50/60 Hz;
Operating Temperature: 10°C-35°C (50°-95°F); Non-operating (storage): -10°-60°C (14°-140°F); Altitude (operating): 2,438
m (8,000 ft.); Operating Humidity: 5% - 80%; Dimensions: 12.17" wide x 5.46" tall x 14.1" long (309mm wide x 138.9mm
tall x 357.4mm long); Weight: 16 lbs 3 ozs.; Storage: Accepts up to eight 3.5" SATA I or II internal desktop hard drives;
Interfaces: USB 2.0 (Admin only), and iSCSI; Drobo Dashboard Application (required for iSCSI): Microsoft® Windows®
Operating Systems, Apple® Macintosh® OS-X v10.5+; File system support: NTFS, HFS+, FAT32, and EXT3.
Drobo Specifications & Systems Requirements – Power Supply: AC Input: 100-240VAC~2.5A, 50-60Hz; DC Output: 12-
17VDC 6.6A & 80W Max.; Drobo Power Consumption: 4A @ 12V (48W); Operating Temperature: 10°C-35°C (50°-95°F);
Non-operating (storage): -10°-60°C (14°-140°F); Altitude (operating): 2,438 m (8,000 ft.); Operating Humidity: 5% - 80%;
Dimensions: 6.0" wide x 6.3" tall x 10.7" long (152.4mm wide x 160mm tall x 271.8mm long); Weight: 6 lbs. 11.3 ozs.
(without power supply); Storage: Accepts up to four 3.5" SATA I or II internal desktop hard drives; Interfaces: USB 2.0 and
FireWire 800 (2nd Generation Only); Drobo Dashboard Application (optional): Microsoft® Windows® Operating Systems,
Apple® Macintosh® OS-X v10.4+; File system support: NTFS, HFS+, FAT32, and EXT3 (via DroboShare).
Drobo S Specifications & Systems Requirements – Power Supply: AC Input: 100-240VAC~2.5A, 50-60Hz; DC Output: 12-
17VDC 6.6A & 80W Max.; Drobo Power Consumption: 4A @ 12V (48W); Operating Temperature: 10°C-35°C (50°-95°F);
Non-operating (storage): -10°-60°C (14°-140°F); Altitude (operating): 2,438 m (8,000 ft.); Operating Humidity: 5% - 80%;
Dimensions: 5.9" wide x 7.3" tall x 10.3" long (150.3mm wide x 185.4mm tall x 262.3mm long); Weight: 8 lbs. (without
power supply); Storage: Accepts up to five 3.5" SATA I or II internal desktop hard drives; Interfaces: USB 2.0, FireWire 800,
eSATA; Drobo Dashboard Application (recommended): Microsoft® Windows® Operating Systems XP SP3+, Apple®
Macintosh® OS-X v10.5+; File system support: NTFS, HFS+, FAT32, and EXT3.
DroboShare Specifications & Systems Requirements – Power Supply: AC Input: 100-240VAC~2.5A, 50-60Hz; DC Output:
12-17VDC 6.6A & 80W Max.; DroboShare Power Consumption: 500mA @ 12V (6W); Operating Temperature: 10°C-35°C
(50°-95°F); Non-operating (storage): -10°-60°C (14°-140°F); Altitude (operating): 2,438 m (8,000 ft.); Operating Humidity:
5% - 80%; Dimensions: 6.0" wide x 1.75" tall x 10.7" long (152.4mm wide x 44.5mm tall x 271.8mm long); Weight: 2 lbs. 4
ozs. (1.02Kg) (without power cable); Network attached storage: Accepts only Drobo storage devices; Interfaces: USB 2.0
st
nd
(for attaching 1
/2
Generation Drobo) and Gigabit Ethernet; Drobo Dashboard Application: Microsoft® Windows®
Operating Systems, Apple® Macintosh® OS-X v10.4+
FCC Compliance & Advisory Statement – This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy
and if not installed and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
1) Reorient or relocate the receiving antenna. 2) Increase the separation between the equipment and receiver. 3) Connect
the equipment into an outlet on a circuit different from that to which the receiver is connected. 4) Consult the dealer or
an experienced radio/TV technician for help. Any changes or modification not expressly approved by the party responsible
for compliance could void the user's authority to operate the device. Where shielded interface cables have been provided
with the product or specified additional components or accessories elsewhere defined to be used with the installation of
the product, they must be used in order to ensure compliance with FCC regulations.
This Class B digital apparatus meets all requirements of the Canadian interference-Causing Equipment Regulations. Cet
appareil numerique de la classe B respecte toutes les exigences du Réglement sur le materiel brouilleur du Canada. Please
see http://www.drobo.com for additional compliancy information.
ii
Downloaded from
www.Manualslib.com
manuals search engine

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

DroboproDroboelite

Inhaltsverzeichnis