5. TROUBLESHOOTING GUIDELINE

PROBLEM
The monitor doesn't operate (no
display)
Current readout gives wrong
polarity (positive current instead
of negative when discharging)
The monitor resets all the time
No changes can be made in the
setup-mode
Not all readouts in normal mode
can be selected
'CHARGE BATTERY' or
18
SBM-01 high precision battery monitor
REMEDY OR SUGGESTION
- Check monitor- and battery
side connections.
- Make sure the inline fuses are
installed and not blown.
- Check battery voltage. Battery
might be flat. Vbatt must be
> 8VDC.
- Try to restart the monitor by
removing/placing the fuses
again.
- Current sense leads from the
shunt are reversed. Check the
installation guide.
- Check the wiring for corrosion
and/or loose contacts.
- Battery might be flat or
defective.
- Check if the setup-lock is OFF
(Function F20)
- Your SBM-01 might be
locked by the super- lock. Ask
the installer for the password to
unlock the monitor using the
PC-link.
- Installer has cancelled some
parameter readouts using the
administrator software with the
PC-link.
- Charge battery full

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für Studer SBM-01

Inhaltsverzeichnis