a.) Installation
Fastening holes (3) are provided for wall mounting. The unit must be mounted against a vertical, fireproof wall with the
connections at the bottom, see above picture, left part. For outside installation the device must also be protected against
exposure to rain and direct sunlight.
b.) Functional description of the appliance
Commission device WITHOUT fence and connection to earth. The control lights flash in time to the impulses (green or
red). The device is ready for operation. If control lights do not flash, the power supply or power supply line must be
checked first. If no fault can be detected, the device should be tested by a specialist.
c.) Functional description with CONNECTED fence system (earthing + fence)
Flashing green:
Control light
Flashing red:
1
fence
(1)
Flashing green:
Control light
Flashing
2
earth (2)
red:
Connection variants:
Fence system closed:
The unit can be operated with a SEPARATE fence system connected to each fence connection (5 – 6).
If both fence exits are used simultaneously, the control light (1) refers to exit (6) with maximum energy.If the indicator
light flashes faster than once per second, the appliance must be disconnected at once and checked by a
technician before it can be used again.
New function in accordance with EN 60335-2-76 A12: 2010
Following a delay time of 15 seconds this device delivers an output energy of no more than 5 joules.
With an increasing load the device increases its output energy after a delay time has lapsed and therefore automatically
adjusts the shock strength to the increased growth, weather conditions and fence status.
Any user of electric fence systems is legally indebted to control the fence-appliance and the fence system regularly, in
accordance with the conditions of use, at least once per day.
visual check of the appliance and the fence system
-
measurement of the minimum voltage of 2500V at each point of the fence
-
Ensure a good grounding of the devices, with at least 3 ground rods, Item No.: 44219.
3
Mains plug is used as ON / OFF!
Connection to 230 V ~!
5
6
This energizer shall not be used 
as an animal trainer  
(inside a barn). 
State of fence ok = output voltage > 3500V = minimum requirement
State of fence faulty = output voltage ≤ 3500V, see operating instructions
enclosed, possible sources of error (fig. 2, pg.5)
State of connection to earth ok; earth voltage < 1000 V
State of connection to earth faulty, earth voltage ≥ 1000 V, see operating
instructions enclosed, possible sources of error (fig. 2, pg.5) and connection to
earth (pg.4)
Erdung
earth
1
2
3
4
5
6
Fence system open:
3
NVi 7000
Indicator light fence
Indicator light earth
Fastening holes
Earth connection
Fence connection
with reduced energy
Fence connection
with maximum energy
earth