P
ROBLEM
ENCOUNTERED
The radiant heater
does not heat
enough.
Dirty marks appear
on the wall around
the radiant heater.
The heating icon
appears on the
screen when the
radiant heater is in
Eco mode.
The panel heater's
surface is very hot.
For radiant heaters equipped with a programming system or controlled via a pilot wire:
The radiant heater is
not responding to
the external pro-
gramming com-
mands.
If you do not succeed in solving your problem, contact your local installer and have the
details of your heater's references, the room's temperature and the programming sys-
tem (if any) to hand.
Increase the temperature settings by pressing the + (E) key.
If the setting is at its maximum, carry out the following checks:
- Check whether there is another heating device in the room.
- Make sure that your radiant heater is only heating the room (door closed).
- Check the supply voltage to the device.
- Check that the power of your radiant heater is adapted to the size of your
room (on average, we recommend 100 W/m² for a ceiling height of 2.50m).
The dirty marks come from the bad quality of the air in the room. In this
case, you are advised to check that the room is correctly aired (ventilation,
vent duct, etc.), that the air is clean and not to smoke in the room. Your
radiant heater will not be replaced under guarantee because of these dirty
marks.
This is normal. The radiant heater can heat to maintain an Eco temperatu-
re.
It is normal for the panel heater to be hot when it is operating; the maximum
surface temperature is restricted in accordance with the NF electrical perfor-
mance standard. However, if you think that your panel heater is still too hot,
check that the output is suitable for the area of your room (we recommend
100W / m2) and that the heater is not placed in a draught, which would inter-
fere with its self-regulation; also check that the installation guidelines have
been followed (curtains, etc.)
Make sure that the central programming system is working correctly (refer
to the user manual), or that the programming control is correctly placed in
its holder and that it is working correctly (check the batteries, fuse, etc.)
Make sure that your radiant heater is in Programming mode and that the
external "Centralised" program is assigned to the right day of the week.