Product Information / Produktinformation A6824 / A6824R
Gateway Card
Interface Modbus over TCP
Connection A6824
Connection A6824R
Data transmission standard:

1.6.2 Power supply

The monitor system voltages are galvanically separated from each other.
Supply inputs
Supply input UB+ / UN+
Supply input UB+ / UN+
Common ground, 0 V U−
Perm. voltage range
Power consumption

1.6.3 Environmental conditions

Application class
Environmental temperature
− Reference temperature
− Nominal use range
Storage, transport temperature
Operating altitude
Relative humidity
Vibration
− Amplitude
− Acceleration
Shock
System of protection
EMC
Allowed degree of pollution
Enviromental Area
RJ 45 socket (front)
RJ 45 socket (back)
ETHERNET 10 base T
two redundant inputs, decoupled via diodes, for
nominal +24V with common ground
d2 / z2
(A6824)
a2 / c2
(A6824R)
b2
(A6824 / A6824)
19 ... 31.2Vdc (IEC 654−2 class DC 4)
CSA: 24Vdc; SELV LPS
max. 3W, at 24V, max. 125 mA
KTF according to DIN 40040
+25°C
0 ... +45°C (CSA
requirement and recommended range
max. range −10°C ... +65°C (not CSA conform)
−40°C ... +85°C
up to 2000m above sea level
≤ 95%, non condensing
according to IEC−68−2 part 6
0,15 mm at 10 ... 55 Hz
2
19,6 mm/s
bei 55 ... 150 Hz
according to IEC−68−2 part 29
Peak value acceleration 98 m/s
Nominal shock duration 16 ms
IP 00, open construction according to DIN 40050
according to EN 50 081−1 / EN 50 082−2
Category 2 (According to IEC 61010−1)
Indoor use only