Herunterladen Inhalt Inhalt Diese Seite drucken

Installing With Gas Supply System - Outdoorchef Hudson Grill 305BX Baugruppe & Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

5. Installing with gas supply system

This product not include the regulator and hose.
The regulator shall comply with EN12864 or EN16129, and the length of hose connecting the appli-
ance to the cylinder shall not exceed 1.5m.
To operate you will need a precision-filled standard G30/G31 grill LP gas cylinder with external valve
threads.
You must have the proper regulator and bottle in order for the barbecue to operate safely and effi-
ciently. Use of an incorrect or faulty regulator is dangerous and will invalidate any warranty.
Connect LP Gas cylinder
Before connecting, be sure that there is no debris caught in the head of the LP tank, head of the
regulator valve or in the head of the burner and burner ports.
Connect gas line to tank by turning knob clockwise until it stops, make sure that the tube is not sub-
ject to twisting.
Pay attention when put the cylinder outside the grill, ensure the hose connect to the cylinder not
touch the hot
surface.
the same cylinder enclosure. Never block the way of shut off the cylinder valve.
Warning: Shut off the gas cylinder when you smell gas.
Disconnect LP Gas cylinder
Before disconnecting make sure the LP gas tank valve in "CLOSED"
Disconnect gas line from LP gas cylinder by turning knob counterclockwise until it is loose.
After connecting to gas cylinder, a leak testing is necessary.
Danger: When changing the gas container, care must be taken to keep away from any source of
ignition.
Leak Testing (To be performed in a well-ventilated area)
Confirm all barbecue control knobs are in the off position.
Open the gas control valve on gas cylinder.
Check for leaks by brushing soap solution over all gas system joints, including all valve connec-
tions, hose connections and regulator connections.
NEVER USE AN OPEN FLAME to test for leaks at anytime.
If bubbles form over any of the joints, there is a leak. Turn off the gas supply and retighten that joint.
Repeat the test. If bubbles form again, stop trying; contact your local dealer for assistance. Leak
test annually, and whenever the gas cylinder is removed or replaced.
24
Keep the cylinder stay in place during operation. Never put spare cylinder in