4.2 Assigning the DMX addresses
GB
4.2.1 Adjusting the DMX addresses
of the spotlights
Adjust the DMX start addresses of the spotlights to
be controlled as follows (
Unit
Adress
Required start addresses of the spotlights
4.2.2 Factory setting
The factory setting can be called easily and quickly
and can e. g. be used for operating the spotlights of
"img Stage Line". The DMX addresses are as-
signed as follows:
Unit 1
Red
001
Red
Green 002
Green 010
Blue
003
Blue
Master 004
Master 012
Configuration of DMX addresses after factory setting
001 – 028 = DMX-adresses
Control RED:
Control GREEN:
Control BLUE:
Control MASTER: adresses 004, 012, 020, 028
Note: By calling the factory settings, not only the
addresses are assigned but also all scenes
(
chapter 5.2) and sequences of scenes
(
chapter 5.3) which have already been pro-
grammed are deleted. If this is not desired, the
addresses have to be assigned manually according
to the table in fig. 4 (
1) Switch off the LC-4LED.
2) Keep buttons RECORD (3) and TAP SYNC (11)
pressed and switch on the control panel again.
3) After switching on, release the buttons. The dis-
play (12) shows "88" for approx. 20 seconds.
Then all LEDs of the control panel flash three
times.
4) As soon as the display shows "00", the ad-
dresses are assigned at the LC-4LED according
to fig. 3.
4.2.3 Manual assignment
If the channel configurations of the connected spot-
lights do not correspond to the factory settings of
the LC-4LED, 4 DMX channels each of a total of
8 channels per spotlight can individually be as-
signed to the controls RED, GREEN, BLUE (7) and
MASTER (9), e. g.:
14
manual of the units):
1
2
3
001
009
017
Unit 2
Unit 3
009
Red
017
Red
Green 018
Green 026
011
Blue
019
Blue
Master 020
Master 028
adresses 001, 009, 017, 025
adresses 002, 010, 018, 026
adresses 003, 011, 019, 027
chapter 4.2.3).
DMX-
channel
1
001 RED
2
002 –
3
003 GREEN 011 GREEN 019 BLUE
4
004 –
5
005 BLUE
4
6
006 –
025
7
007 –
8
008 MASTER 016 –
Manual assignment of DMX channels to the controls
RED, GREEN, BLUE and MASTER in case of spotlights
with different DMX configurations
001 – 032 = DMX-adresses
1) Keep button PATCH/DOWN (15) pressed until
the red LED of the button lights up.
Unit 4
2) Use one of the buttons FIXTURE (1) to select the
025
unit of which the DMX channels are to be as-
signed. The corresponding blue LED lights up.
3) Keep the button (8) below control RED (7)
027
pressed and then press additionally the button in
the field SCENES (2) the number of which cor-
responds to the DMX channel for the control of
the red LEDs (SCENES 1 = DMX channel 1, ...,
SCENES 8 = DMX channel 8) and keep the but-
ton pressed.
4) First release the button below control RED (all
LEDs of the control panel flash three times) and
then the corresponding button in the field
SCENES. The selected DMX channel is thus
assigned to the control RED.
5) Repeat the steps 3 and 4 for the controls
GREEN, BLUE and MASTER.
6) For assigning further units repeat the steps 2 to
5 in each case.
7) An incorrect assignment may be corrected by
repeating the steps 2 to 5.
8) To deactivate the mode of assignment, keep but-
ton PATCH/DOWN pressed until the red LED of
the button will be extinguished.
5 Operation
1) Use the buttons FIXTURE (1) to select the units
to be operated. The corresponding blue LEDs of
the buttons light up.
2) Advance control MASTER (9) by approx.
control range and adjust the desired lighting
colour with the controls RED (7) for the red LEDs,
GREEN for the green LEDs and BLUE for the blue
LEDs. Advance the control of which the colour is
to dominate to maximum and adjust the desired
shade of colour with the other two controls.
Unit 1
Unit 2
009 MASTER 017 RED
010 RED
018 GREEN 026 GREEN
012 BLUE
020 MASTER 028 –
013 –
021 –
014 –
022 –
015 –
023 –
024 –
Unit 3
Unit 4
025 RED
027 BLUE
029 –
030 –
031 –
032 MASTER
1
⁄
of its
3