The display will automatically show the factory timer reading, i.e. 6,000 hours.
If the BactoDose had already been used previously, and is switched on again, the
display will indicate the timer reading the pump head had at the time the BactoDose
was switched off earlier. If you had increased or reduced the value of the time meter
yourself, the display will indicate the latest counter reading it had before it was
switched off.

Status overview

Drawing 5
The time of day (in 24-hour format) will be displayed by briefly pressing the button
once. The status overview of the dosing pump (dP) will be shown by briefly pressing the
button again. Here, you will be able to see how many seconds of dosing are taking place
per hour. Dosing with dosing pump 1 is therefore possible up to 24x per day.

Navigating through the menu

Drawing 6
Pressing the button for 1x 3 seconds will take you to the main menu. The main menu
contains 3 control menus for the different applications. By briefly pressing the button,
you will be able to navigate through these various control menus. As soon as you have
reached the desired control menu, it can be selected by again pressing the button for
3 seconds.
Hr: Setting the time meter of the pump head
dP:
Adjusting the dosing pump
tSEt: Adjusting the time
Setting the time meter for the pump head (Hr).
Drawing 7
As a result of wear and tear, the pump head must be replaced after 6,000 hours. If you
wish, the hour counter can be set higher or lower. The timer can be reset to 6,000 hours
after the pump head has been replaced after 6,000 hours.
Pressing the button 1x 3 seconds will take you to the main menu, where first 'Hr' will
appear on the display. By pressing the button once again for 3 seconds, you will enter
the menu relating to the operating hours of the pump. The default value is set to 6,000
hours. If you wish, the operating hours of the pump can be modified in this menu by
steps of 500 hours. By pressing the button briefly in the 'Hr' menu, it is possible to
select between 'rSt', 'UP' and 'dn'. One of these selections can be confirmed by again
pressing the button for 3 seconds.
rSt: This option will reset the meter indication to value 6,000 by keeping the
pushbutton down for 3 seconds. After this, the time meter will start counting
down again from 6,000 hours.
UP: By briefly pressing the pushbutton, the counter value can be increased from
6,000 in steps of 500 to a maximum value of 9999. Ten seconds after the push-
button has been released, the count-down from the selected value will start.
dn: By briefly pressing the pushbutton, the counter value can be decreased from
6,000 in steps of 500 to a minimum value of 0000. Ten seconds after the push-
button has been released, the count-down from the selected value will start.
The timer will indicate that the pump head must be replaced as follows:
- From hour position 0672, the display will blink every second. The pump head is to be
replaced in 4 weeks' time.
- From hour position 0336, the display will blink every half second. The pump head
needs to be replaced in 2 weeks' time.
- From hour position 0168, the display will blink every 1/4 second. The pump head
needs to be replaced in 1 weeks' time.
- At an hour position of 0000, the digits will blink continuously, and the meter will not
continue to count down. The pump head needs to be replaced.
Adjusting the dosing pump (
Drawing 8
Pressing the button 1x 3 seconds will take you to the main menu, where first 'Hr' will
appear on the display. If you now briefly press the button again, 'dP' will appear. You
can select this menu by keeping the button down for 3 seconds.
)
dP
In the 'dP' menu, you will be able to select from 24 pump positions by briefly pressing
the button. This will enable you to set the number of seconds the BactoDose must be
active for every hour of the day. As there are 24 hours in a day, you will also be able to
enter the number of seconds 24 times. These positions are linked to the real-time clock.
Position 01 is 1 a.m. at night, and position 20 is 8 p.m. (20:00 hrs) in the evening. As
soon as you have reached the position (i.e. the time) you would like to select, it is
possible to confirm this by again pressing the button for 3 seconds. If you then briefly
press the button, you will be able to switch between 'UP' and 'dn' with the position
(time) behind it. If you would like to increase the number of seconds at midnight, you
will see 'UP00' on the display.
UP: By briefly pressing the pushbutton, the timer value can be increased from 0
seconds up to a maximum value of 120 seconds in steps of 1 second. If you keep
the pushbutton pressed down for 3 seconds, you will be able to continue setting
the other pump positions. Ten seconds after the pushbutton has been released,
the system will start with the values you have indicated.
dn: By briefly pressing the pushbutton, the timer value can be decreased down to a
minimum value of 0 seconds in steps of 1 second. If you keep the pushbutton
pressed down for 3 seconds, you will be able to continue setting the other
positions. Ten seconds after the pushbutton has been released, the system will
start with the values you have indicated.
ATTENTION:
• 1 sec = 0.5 cc
based on a viscosity (liquid thickness) equal to water
• Max. dosage time: 120 sec. per hour
Setting the clock (tSEt)
Drawing 9
Pressing the button 1x 3 seconds will take you to the main menu, where first 'Hr' will
appear on the display. Then briefly press the button again twice, after which 'tSEt' will
appear. Holding the button once again for 3 seconds will take you to the clock menu.
In this menu, it is possible to modify the hours of the day in steps of one hour by briefly
pressing the button. Press the button for 3 seconds as soon as you have reached the
correct hour. Then will then be able to adjust the minutes. The minutes will increase
by 1 minute each time the button is briefly pressed. If the button is pressed for a longer
period of time, the minutes will start running faster. Release the button as soon as the
correct time is shown on the display. Ten seconds after the pushbutton has been
released, the correct time has been entered and the time meter will be displayed again.
ATTENTION:
The clock only operates in 24-hour format.
Please note that the clock must be reset after there has been a power cut.
You should therefore always ensure that the device is supplied with
electricity whenever it is in use.
Dismantling / Maintenance
Replace the pump head once a year (Drawing 2).
Always switch off the power supply during maintenance/dismantling of the device.
1 Unscrew the screws
.
(E)
2 Remove the pump head
from the housing
(F)
3 Place the new pump head
onto the housing
(F)
Technical specifications for the dosing pump
• Weight:
0.7 kg
• Dimensions l x w x h:
80 x 90 x 215 mm
• Consumption:
5 Watt
• Rotation:
30 rpm
• Voltage:
230V
• Frequency:
50/60 Hz
.
(G)