Herunterladen Inhalt Inhalt Diese Seite drucken

Factory Setting - Helo HNS T1 Produkthandbuch

Vorschau ausblenden Andere Handbücher für HNS T1:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 60
User and installation manual HNS-T1
Settings
The following submenus are found under the menu
-
Status. Shows the temperature and the time
-
Set the time. Time setting.
-
Language. You can select the language from a menu.
-
Display. Setting the display to sleep, time setting 3–60 s.
-
Automatic locking. Locks the buttons after 15– 60 seconds,
on/off.
-
Vibration. Vibration function of the controller on/off.
-
Service. Enter the PIN code to access the service menu.
The service PIN code is 124.
Service
The following submenus are found under the menu
-
Maximum time. In steam bathing use 0–24 hours.
-
Maximum temperature. Temperature setting 20–55℃.
-
°C or °F. Alternative temperature display.
-
24 or 12 hours. Alternative time display.
-
Light switch. Lighting controls, continuous or momentary.
Continuous, the lights are always on when the steam generator is on.
Momentary, lights are only on when the light button is pressed.
Scent – Fan.
-
Scent pump control on/off.
Fan, Air conditioning control after the steam generator has stopped.
Automatic 30 minutes.
Time with manual setting 20–60 minutes.
Manual control on/off.
-
Decalcification. Decalcification alarm limit setting 0–100 hours.
Show an alarm on the display after the hour setting is up.
Operation time. Steamer operation time counter.
-
Factory setting. PIN code 421.
-
Test. During service or in case of a fault you can test
different relay outputs and check that they work.

Factory setting

-
Select the region where the controller is used
-
Europe, time and temperature settings according to the
European regulations.
-
USA, settings according to the American regulations
-
Other regions.
-
Select Europe. Select the control panel language
from the language menu, English, Swedish or Finnish.
-
Select the control panel use, sauna or steam bathing.
Select steam bathing and press OK.
Set the maximum steam bathing time 0–24 hours.
Set the time in the control panel.
Settings
Status
Set the time
Display
Automatic locking
Vibration
Service
Service
Maximum time
Maximum temperature
O
O
C or
F
24 or 12 hours
Light switch
Scent – Fan
Decalcification
Factory settings
Test
Select region
Europe
USA
Other regions
17

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Inhaltsverzeichnis