Table 1 LED/category chart
NOTE: See Faults and warnings (pages 21-22) for a detailed description of status, faults and warnings associated
with each LED.
Device OK
Alarm
Activity
Status
Mains power not available
Power
Frame/Amp fault active
Load
Frame fault active
Amp
Input signal below present
threshold or Frame/Amp
Signal
fault active
Mute
Device not selected
Select
OFF
Green
N/A
Device active in an active
N/A
system
Device configured and ready
N/A
to participate in a system
Device is ON
Load OK
Amplifier channel OK
Signal above signal
present threshold
N/A
Not muted
Device selected
Amber
Frame warning/Minor
Tesira fault active
Device is part of an inactive
N/A
Device is ready and waiting to
Device is not ready to receive
receive a configuration
Device in STANDBY
Load warning active
Amplifier channel
warning active
N/A
Signal clip or limit/fault active
N/A
N/A
D SERIES Tesira Quick Start Guide rev 2.0.0
11. Product overview
Red
Frame fault/Major
Tesira fault active
system (audio stopped)
a configuration
Device in SLEEP
Load fault active
Amplifier channel
fault active
Muted