Herunterladen Inhalt Inhalt Diese Seite drucken

Ballu-Biemmedue FARM 85 Bedienungsanleitung Seite 36

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 24
• Secure the gas valve group to the machine using the M8 and M5
screws.
• Connect the stainless steel hose to the burner, taking care to
properly insert the N gas seal:
• Locate the cable with 6-pin Wieland plug running out of the gas
valve group and insert the plug into the burner socket;
• Apply one of the two stickers with the serial number on the
nameplate of the machine characteristic data:
• Apply the second sticker with the serial number on the Assembly
and Installation Declaration contained in the user manual:
L-L 255.00-RK
EN
N
• The burner is not pre-adjusted by the manufacturer and must be
set
according
to
data
Characteristics of the user manual: follow the instructions in the
manual to complete the connection of the machine to the gas
supply system and for commissioning
Warning
Check all threaded connections on the gas line.
When commissioning, check for any gas leaks or
seepages using soap and water
4.5. CONNECTION TO FUEL SUPPLY
Warning
The heater must be installed, set up, and used in
compliance with all applicable regulations.
Warning
Before installing, check the gas supply conditions
required for the type of gas chosen and for the EU country
of installation (Tables I and II).
The gas supply pipe must be properly sized, conform to the installed
thermal power, and guarantee the necessary conditions for gas
supply.
Warning
The gas supply pressure must be guaranteed during
heater operation and not with the heater off.
The space heater has a gas ramp with: gas filter, pressure regulator,
safety electrovalve, work electrovalve, pressure stabilizer, pressure
valve.
It is good practice for the installer to set up the supply line as
follows:
1: filter-pressure regulator or filter
3: stopcock
Parts (1), (2) and (3) are available as accessories and are not
supplied with the heater.
When the line has been connected:
• Bleed the gas supply pipe;
• Check that the gas pipe is sealed.
• Open the gas stopcock and check the seal of all connections to
the heater.
4.6. CONNECTING BURNER TO "SNORKEL" DEVICE AND SETTING
COMBUSTION AIR
The burner air intake (3) can be connected outside the room to be
reported
in
Table
of
Technical
2: antivibration joint
4: gas ramp
36 / 80

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Farm 110Farm 145Farm 185Farm 235

Inhaltsverzeichnis