Herunterladen Inhalt Inhalt Diese Seite drucken

Inputs And Outputs; Sms Outputs (Sms1 - Sms4) - Conrad GX106M Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

You can also have this service blocked again. To do so, send an SMS with the text "Deactivate e-
mail" to the provider's gateway number.
The phone number must be transmitted so that the module can detect who called or sent an SMS. Refer
to the manual of your mobile phone to see how to activate this function.
Provider
Gateway
E-mail
activate
E-mail
deactivate
Fax prefix
Contact your provider for the current prices and settings.

6.7 Inputs and outputs

Attention:
This is an autonomous alarm signalling device. Wring settings or connections may
lead to undesired SMS dispatch!
Possible errors are e.g.:
- the applied voltage at IN1 and/or IN2 is exactly at the switching threshold of the two
optocouplers
- the applied voltage at the ADC fluctuates by the set limit value
- the temperatures at T1 and/or T2 fluctuate by the set limit value
6.8 4 SMS outputs (SMS1 – SMS4)
These are the four outputs SMS1 to SMS4 that can be activated/deactivated by sending an SMS or e-
mail to the module. You can directly connect a relay to these outputs (CONRAD order no. 502892). This
relay can switch 8 Ampere at 250V AC or at 24V DC.
For each of the four outputs, you can assign a (different) message text each. This text serves to address
the output.
T-Mobile
8000
OPEN
CLOSE
99 German
98 English
Vodafone D2
3400
OPEN
CLOSE
99
88 with ads
E-Plus
7676245
START
STOP
1551
O2
6245
any
STOP
329
37

Werbung

Inhaltsverzeichnis
loading