1. Installation (Space)
• Product with fl ammable refrigerants,
shall be installed according to
the minimum room area, Amin
(m²) mentioned in Table A of the
Installation Instructions.
• In case of fi eld charge, the effect
on refrigerant charge caused by
the different pipe length has to be
quantifi ed, measured and labelled.
• Must ensure the installation of pipe-
work shall be kept to a minimum.
Avoid use dented pipe and do not
allow acute bending.
• Must ensure that pipe-work shall be
protected from physical damage.
• Must comply with national gas
regulations, state municipal rules
and legislation. Notify relevant
authorities in accordance with all
applicable regulations.
• Must ensure mechanical
connections be accessible for
maintenance purposes.
• In cases that require mechanical
ventilation, ventilation openings shall
be kept clear of obstruction.
• When disposal of the product, do
follow to the precautions in #12 and
comply with national regulations.
Always contact to local municipal
offi ces for proper handling.
ACXF55-27151.indb 9
ACXF55-27151.indb 9
2. Servicing
2-1. Service personnel
• The system is inspected, regularly
supervised and maintained by
a trained and certifi ed service
personnel who is employed by the
person user or party responsible.
• Ensure the actual refrigerant charge
is in accordance with the room
size within which the refrigerant
containing parts are installed.
• Ensure refrigerant charge not to
leak.
• Any qualifi ed person who is involved
with working on or breaking into
a refrigerant circuit should hold
a current valid certifi cate from an
industry-accredited assessment
authority, which authorizes their
competence to handle refrigerants
safely in accordance with an
industry recognised assessment
specifi cation.
• Servicing shall only be performed
as recommended by the equipment
manufacturer. Maintenance and
repair requiring the assistance of
other skilled personnel shall be
carried out under the supervision of
the person competent in the use of
fl ammable refrigerants.
• Servicing shall be performed only as
recommended by the manufacturer.
9