Herunterladen Inhalt Inhalt Diese Seite drucken

Instructions For Use; Safety Recommendations For Use; Starting And Stopping The Pump - Annovi Reverberi XJS Serie Betriebs Und Installationsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 48

Safety recommendations for use

Before start-up, the operator must perform the necessary safety checks.
Before starting up the pump check that the water supply hose is connected properly; use of the pump
without water will damage it.
In the event of leaks from the pressurised pipes, stop the pump at once and remove the cause of the
leak.
Do not operate the pump above the limits set by the manufacturer to increase its performance.
If the system is to be shut down with ambient temperatures close to 0 °C, run the pump without water
for 10 seconds with the end of the delivery pipeline open to empty the system and pump of water and
prevent ice from forming.

Starting and stopping the pump

To start the pump, proceed as described below.
1) Turn on the water supply.
2) Start up the motive power source to operate the
pump.
For easier starting in models with pressure regu-
lator, operate the knob (A) to start up the pump
with no pressure present.
Wait for the motive power source to reach the
correct running speed and then turn the knob
to pressurise the pump to the normal working
pressure.
For easier starting in models without pressure
regulator, turn on the pressurised water delivery
device.
To stop the pump, proceed as described below.
1) Stop the motive power source to stop the pump.
2) Turn off the water supply.
3) Turn on the pressurised water delivery device to discharge the residual pressure from the pump.
English

INSTRUCTIONS FOR USE

UN003478-BU
27
A
6
Use and Installation

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis