Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

6. WIRING

6.1.
POWER AND CONNECTION WIRING
The connection cables must comply with the specifications listed in the table below.
MODEL
Indoor power supply wires
2
(mm
)
Outdoor power supply wires
2
(mm
)
2
Connection wires (mm
)
Connect the power supply to the outdoor unit and conduct the wring connection as shown
on the below diagram:
Model 18K / 24K / 36K / 42K (Single-phase)
Outdoor unit
Models 48K / 60K (Three-phase)
Outdoor unit
N.B.
The connection wire of indoor units should be connected to the corresponding
-
terminal board; otherwise it will cause the unit failure or even damage the units.
Connect the grounded wire correctly, otherwise will cause the malfunction of some
-
electrical component and shock or fire indeed.
Don't reverse the power polarity.
-
-
Must fix the screw nail of the firmly wire, then drag the wire lightly, confirmation
whether it's firmly.
18K
24K
2x1,5+T
2x1,5+T
2x2,5+T
2x2,5+T
Indoor unit
90
36K
42K
2x1,5+T
2x1,5+T
2x6,0+T
2x6,0+T
2x0,75
Indoor unit
48K
60K
4x1,5+T
4x1,5+T
4x2,5+T
4x2,5+T

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis