4.4 Technical data table
Data
Product identification codes G20
Product identification codes G31
Countries of destination
Gas category
Maximum heat capacity
Minimum heat capacity
Maximum heat capacity
Minimum heat capacity
Performance at max. power
Burner injectors G20
Gas supply pressure G20
Maximum gas delivery G20
Minimum gas delivery G20
Burner injectors G31
Gas supply pressure G31
Max. gas delivery G31
Min. gas delivery G31
NOx emission class
Max. operating pressure
Min. operating pressure
DHW delivery ∆25º
DHW delivery ∆30º
Degree of protection
Supply voltage
Absorbed electrical power
Empty weight
Type of unit
Units
11
GCL1MKKA
GCL1MLKA
IT - ES - PT - FR - GB - BE
II2HM3P (IT) - II2H3+ (ES - PT - GB)
II2E+3+ (FR) - I2E+ (BE) - I3+ (BE)
kW
21.1
kW
8.1
kW
18.9
kW
7.0
%
88.5
no. x Ø
12 x 0.85
mbar
20
m
/h
2.23
3
m
/h
0.86
3
no. x Ø
12 x 0.50
mbar
37
m
/h
1.64
3
m
/h
0.63
3
-
bar
10
bar
0.2
l/min
11
l/min
5.5
IP
X4D
V/Hz
W
/
Kg
9.50
Rev. 00 - 11/2018
14
GCI1PKKF
GCI1PLKF
26.8
10.7
23.8
9.3
88.7
14 x 0.85
20
2.84
1.13
14 x 0.50
37
2.08
0.83
6 (<56 mg/kWh)
10
0.2
13.7
6.9
X4D
230 V/50 Hz
/
13.50
B11BS
Q
Q
NOx
MSP
29