Herunterladen Inhalt Inhalt Diese Seite drucken

Possible Failure And Its Solution - Lincar 138 Aurora Bedienungs- Und Wartungsanleitung

Geräte für feste brennstoffe
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 78

Possible failure and its solution

3.4
DEFECT
Windows fire door
and/or combustion
chamber are dirty of
black fumes.
Not regular draft
Too much dark
fumes from the
exhaust fumes
Fumes escape from
the equipment.
Every intervention has be done from qualify staff !
Every repairs must be done by our authorized assistance centre.
Lincar S.r.l. is not responsible for damages to thing or people due to a wrong installation,
equipment tampering, improper use, bad maintenance or no observation of normative in
force. If considerate appropriate, Lincar S.r.l. reserves the right to make modifications without
notice and in every moment.
Some particulars and accessories illustrated in this handbook are not mass produced item so
its extra costs are to check at contract release.
CAUSE
− Low draft <10 Pa.
− Wrong regulation.
− Too much combustible
introduced.
− Combustible with high
humidity level.
− Not good quality
combustible.
− Flue / exhaust fumes
unsuitable or dirty.
− Appliance is dirty inside.
− Appliance light on with green
wood.
− Appliance dirty inside.
− The fire/ash door is open
while the fire is burning.
− Draft insufficient.
− Not correct regulation during
ignition operation
− The appliance should be
cleaned.
39/96
IT-GB-FR-ES-DE mod. 138
SOLUTION
− Check that the exhaust fumes
tube is not obstructed.
− Modify the flue : increase the
flue's high, end units not correct,
improve the isolation / seal
− Read the chapter "Regulations".
− Reduce the quantities.
− Employ dried wood.
− Read the chapter "Combustible".
− Require chimney sweep
intervention.
− Clean the appliance.
− Light on the appliance with dried
wood.
− Call the assistance service.
− Close the door.
− Call the chimney – sweeper to
check the chimney flue.
− Read the chapter "Regulations"
and "Combustible to employ".
− Clean all the connection tubes
and the chimney.

Werbung