1.4 Connection

Before connection check technical data reported in the technical plate ( Chap. 4 ) and
control that it correspond to the ones required in the order.
All heating biomass equipment especially wood stove has to evacuate the combustion
products in a flue built in conformity with normative in force.
The following instructions describes „ informations for a good installation „ and it refers
to a normative in force but it are not to be consider exhaustive for installations laws.
COLLAR EXHAUST FUMES ASSEMBLY
The equipment is provided by collar exhaust fumes for a vertical connection , anyway it's
possible also the back connection.
Vertical exhaust fumes collar
Place the collar over the plate (Fig.1) and fix it to
the plate employing the enclosed screws. Be
careful to employ the screws in the right way.
For every version of Mod. Gaia....
Place the collar over the plate into special
place.
HANDRAIL ASSEMBLING
For every Mod. Gaia... Fig.2
To insert the caps "D" on terminals
support "C".
To insert the support "C" in tube "A"
than fix it to the plate frame with
screws "F" interposing the connection
ring "B".