Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Installation - Duravit Blue Moon Montageanleitung

Mit wannenverkleidung (freistehend)
Vorschau ausblenden Andere Handbücher für Blue Moon:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4

Electrical installation

Power supply
Max. nominal output of heating element
Max. nominal output of whirl system
Fuse protection
RCD
All-pole separating main switch
Safety areas in accordance with DIN VDE 0100-701
6 0
6 0
0
0
0
0
6 0
6 0
1
1
2
2
3
3
0
0
Pre-installation
> Installing 2 permanent power supply lines:
• Pre-connect a separate fuse and residual current
operating device (RCD)
• Pre-connect an all-pole separating main switch
outside the prescribed safety areas (0 - 2)
• Allow the supply line to protrude by 3,000 mm
> Laying the potential equalisation cable:
• Allow the cable to protrude by 3,000 mm
14
Connecting the pool (Diagram 14)
NOTE! Avoiding any malfunctions!
• Do not fasten the cables together with cable ties.
• Do not install the supply lines parallel to the con-
trol cables.
Unfasten the protective cover, if there is one.
I
Connect a supply line to the mains supply socket
II
of the heater.
Connect a supply line to the mains supply socket
of the controls.
III
Connect the potential equalisation cable to the
pool's potential equalisation.
Fasten the protective cover again, if there is one.
IV
* or the height of the highest
shower head / water outlet
that is permanently installed,
depending on which is higher
71xxx xx 8 xx00: 50 Hz, 220 - 240 V AC
71xxx xx 8 xx06: 60 Hz, 220 - 240 V AC
3 KW
3 KW
I
= 16 A
N
I
≤ 30 mA
ΔN
I
II
III
L
N
PE
IV
POOL_M_BlueMoon_FST_MV-AV/12.03.1.
7

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Blue moon 710143Blue moon 710169

Inhaltsverzeichnis