Herunterladen Inhalt Inhalt Diese Seite drucken

Modster DUO SMART CHARGER 600 Betriebsanleitung Seite 20

Quelle: modster.at
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

F
User Manual
STANDARD BATTERY PARAMETERS
Be EXTREMELY careful to choose the correct voltage settings based on the
cells and chemistry of the battery being charged. Failure to do so may result in
battery damage, explosion, or fire!
CONFIRMING CHARGE CURRENT
It is critically important to understand the maximum charging current
for the battery pack to be charged. Excessive charge current can
significantly reduce the life of a battery, or in severe cases a fire or
explosion.
The charge and discharge current of a lithium battery is determined
by its "C" rating. Most batteries indicate the C rating of the pack on the
main label. Multiply the C rating of the battery pack by the capacity to
determine the safe and proper charge current. For example, a 1.000mAh
battery with a 5C rating means that the maximum charge rate should be
1.000 (capacity in milliamps) X 5 (C rating) = 5.000mAh. Therefore, the
maximum charge rate for a 1.000mAh 5C lithium battery should be 5A
20