Herunterladen Diese Seite drucken

Installation; Technical Characteristics - urmet 1158/48 Bedienungsanleitung

Modul mit spule für hörbehinderte

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 6
ENGLISH
ILA (Induction Loop Antenna) T-coil module Ref. 1158/48 allows hard of hearing to hear door unit audio
conversations with the hearing aid. The hearing aid must be equipped with a T-magnetic interface.
Module with
door unit
T-Coil module for
hard of hearing people
Button module

INSTALLATION

~0
~12
12Vdc or Vac
power supply
Ref. 1145/500
door unit
4
20cm max.
Set the switch
to T mode
~0
~12
12Vdc or Vac
power supply
Ref. 1145/67
door unit
DS1158-007A
~0
~12
12Vdc or Vac
power supply
Ref. 1072/8
door unit
TERMINAL PINS DESCRIPTION
ILA
ILA two terminal pins to be connected to ILA terminal
~12
12Vac or 12Vdc power supply
~0
power supply ground
§
A power supply device dedicated to Ref. 1158/48 module is needed.

TECHNICAL CHARACTERISTICS

Power supply voltage ................................................................................................................. 12V ac or dc
Max. current consumption ..................................................................................................... 100mA @12Vcc
Operating temperature range ......................................................................................................... -5 ÷ +45°C
DS1158-007A
To ILA terminal pins
~12
12Vcc or Vac
of 2Voice or
power supply
~0
Ipervoice modules
200mA @12Vca
5

Werbung