Electrical Connection
WARNING
This appliance should be properly grounded for your safety. The
power cord of this appliance is equipped with a three-prong plug
which mates with the standard three prong wall outlets to mini-
mize the possibility of electrical shock.
Do not, under any circumstances, cut or remove the third ground
prong from the power cord supplied.
This freezer appliance requires a standard 220-240VAC 50Hz
electrical outlet with three-prong ground.
This freezer appliance is not designed to be used with an invert-
er.
The cord should be secured behind the appliance and not left
exposed or dangling to prevent accidental injury.
Never unplug the freezer by pulling the power cord. Always grip
the plug firmly and pull straight out from the receptacle.
Do not use an extension cord with this appliance. If the power
cord is too short, have a qualified electrician or service techni-
cian install an outlet near the appliance. Use of an extension cord
can negatively affect the performance of the unit.
Improper use of the grounded plug can result in the risk of elec-
trical shock. If the power cord is damaged, have it replaced by an
authorized service center.
Climate Range
The information about the climate range of the appliance is pro-
vided on the rating plate. It indicates at which ambient tempera-
ture (that is, room temperature, in which the appliance is work-
ing) the operation of the appliance is optimal (proper).
Climate range ............................ P ermissible ambient temperature
SN ................................................................... from +10°C to +32°C
N . .................................................................... from +16°C to +32°C
ST . ................................................................... from +16°C to +38°C
T ..................................................................... from +16°C to +43°C
Note:Given the limit values of the ambient temperature range
for the climate classes for which the refrigerating appliance is
designed and the fact that the internal temperatures could be af-
fected by such factors as location of the refrigerating appliance,
ambient temperature and the frequency of door opening, the
setting of any temperature control device might have to be var-
ied to allow for these factors, if appropriate.
If the power cable is damaged, it must be replaced by the manu-
facturer, its service agent or similarly qualified persons in order
to avoid a hazard.
Locks
If your Freezer is fitted with a lock, keep the key out of reach and
not in the vicinity of the appliance to prevent children being en-
trapped. When disposing of an old Freezer, break off any old
locks or latches as a safeguard.
Freon-free
The freon-free refrigerant (R600a) and the foaming insulation
material (cyclopentane) that is environmentally friendly are used
for the freezer, causing no damage to the ozone layer and having
a very small impact on the global warming. R600a is flammable,
and sealed in a refrigeration system, without leakage during
normal use. But, in case of refrigerant leakage due to the refrig-
erant circuit being damaged, be sure to keep the appliance away
from open flames and open the windows for ventilation as quick-
ly as possible.
Product Features
1
Control panel
2
Flip cover
3
Freezer drawers
4
Adjustable Feet
Due to technological innovations, the product descriptions in this
manual may not be completely consistent with your freezer. De-
tailed information is in accordance with the final product.
Preparations for use
Installation location:
Ventilation condition
The position you select for the freezer installation should be
well-ventilated and has less hot air. Do not locate the freezer
near a heat source such as cooker, and avoid it from direct sun-
light, thus guaranteeing the refrigeration effect while saving en-
ergy consumption. Do not locate the freezer in the damp place,
so as to prevent the freezer from rusting and leaking electricity.
The result of the total space of the room in which the freezer is
installed being divided by the refrigerant charge amount of the
freezer shall not be less than 8 g/ M3.
Note: The amount of refrigerant charged for the freezer can be
found on the nameplate.
Heat dissipation space
When working, the freezer gives off heat to surroundings. There-
fore, at least 300 mm of free space should be spared at the top
side, more than 100 mm on both sides, and above 50 mm at the
back side of the freezer.
Level ground
Place the freezer on the solid and flat ground (floor) to keep it
stable, or else, it will give rise to vibration and noise. When the
freezer is placed on such flooring materials as carpet, straw mat,
polyvinyl chloride, the solid backing plates should be applied un-
derneath the freezer, so as to prevent color change due to heat
dissipation.
Unobstructed ventilation shall be maintained around the appli-
ance or in an embedded structure.
8