Installation
Material losses
!
The strainer must be fitted for the appliance to func-
tion.
» When replacing an appliance, check whether
the strainer is installed (see chapter "Mainte-
nance").
Removing/replacing the flow limiter
Note
If you use a thermostatic valve, the flow limiter must
not be removed.
1 Plastic profile washer
2 Flow limiter
» Remove the flow limiter and refit the plastic profile
washer.
DDLE LCD 18/21/24: Replacing the flow limiter
» If 24 kW connected load has been selected, replace
the fitted flow limiter (white) with the flow limiter sup-
plied (orange, fixed to the cold water pipe).

Making the electrical connection

WARNING Electrocution
Carry out all electrical connection and installation
work in accordance with relevant regulations.
WARNING Electrocution
The connection to the power supply must be in the
form of a permanent connection in conjunction with
the removable cable grommet. Ensure the appliance
can be separated from the power supply by an iso-
lator that disconnects all poles with at least 3 mm
contact separation.
WARNING Electrocution
Ensure that the appliance is earthed.
Material losses
!
Observe the type plate. The specified voltage must
match the mains voltage.
» Connect the power cable to the mains terminal (see
chapter "Specification / Wiring diagram").
24
L1 '
2
1
2
DDLE LCD 18/21/24: Re-plugging the coding
card
In its delivered condition, the appliance is plugged to
21 kW. When changing to a different connected load,
carry out the following steps:
» Re-plug the coding card according to the selected
connected load (for selectable connected load and
fuse protection of the appliance, see "Specification /
Data table").
» Tick the selected connected load on the type plate.
Use a ballpoint pen to do this.
Fitting the base part of the back panel
3
L3 '
4
L2 '
1
L1 '
2
» Position the lower back panel on the main back
panel and click it into place.
» Align the mounted appliance by undoing the fixing
toggle, aligning the power supply and back panel,
and then re-tightening the fixing toggle. If the back
panel is not flush with the wall, the appliance can be
secured at the bottom with two additional screws.