Installation – for qualified contractors
8.1.2 Hoz 5 Comfort - Oversink installation
Material losses
!
The Hoz 5 Comfort is designed exclusively for over-
sink installation. The water connections of the ap-
pliance point downwards.
Material losses
!
Connecting hose length (from tap to appliance) may
not exceed 1 m.
For connecting hoses > 1 m:
» Install a tube aerator attachment in the overflow
line.
9. Installation
9.1

Appliance installation

» Mark out the drill holes using the installation template
(see middle part of these instructions).
» Drill the holes and insert suitable rawl plugs.
» Secure the wall mounting bracket using suitable
screws.
» Hang the appliance on the wall mounting bracket.
16
e

9.2 Water connection

Material losses
!
Carry out all water connection and installation work
in accordance with regulations.
Material losses
!
The appliance may develop a leak and cease func-
tioning.
» Never subject the appliance to water pressure.
» Never interchange the water connections.
» Set the flow rate (see tap instructions). Observe
the maximum permissible flow rate with a fully
opened tap (see chapter "Installation / Specifi-
cation / Data table").
Material losses
!
Counterhold with a suitable spanner when tighten-
ing fittings.
Huz 5 ÖKO Comfort
SW22
SW19
Match up the colour coding on the tap water connections
and the appliance:
◦ R.h. side blue = "Cold water inlet"
◦ L.h. side red = "DHW outlet"
» Secure the water connections from the tap to the
appliance.
Note
Ensure that the water connections are not kinked
during installation. Prevent any tensioning during
installation.
Hoz 5 Comfort
» Secure the water connections from the tap to the
appliance.
Note
The levers for the twin-lever mixer tap for oversink
installation are delivered DIN 44897-compliant:
◦ Cold water on the left (blue)
◦ Hot water on the right (red)