Herunterladen Inhalt Inhalt Diese Seite drucken

Main Characteristics; Technical Characteristics - Watts Water Technologies LCD+ Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Menu structure
Service
English "Language"
Time and date
o
Time
o
Date
o
24/12h clock
o
DST
System
o
System 1 - 8
o
System Parameter (if available)
Outputs Configuration
P1 "Information of the use"
o
P2 "Information of the use"
o
P3 "Information of the use"
o
Inputs Configuration
o
Fixed Flowrate value
o
Grundfos sensors
o
Impulse flow meter
o
Temperature Sensors
Energy Measurements
o
Solar Energy
nd
o
2
Protection func.
o
Max temp coll.
o
Overheat prot.
o
Cooling
o
Recooling
o
Freeze prot.
Degrees °C/°F
Tube collectors
Factory setting
Quick start menu
o
Configuration sequence
Settings
Maxtemp tank1
dT.ON tank1
dT OFF tank1
"Only available with system with 2 tanks"
Maxtemp tank2
dT.ON tank2
dT OFF tank2
"Only available with system 6"
dT.ON return
dT OFF return
dT FS
Mintemp coll.
"Only available if P3 is used as an Extra function"
Extra Function adjustments
Operation
Automatic
Off
Chimney sweep
Manual testing
Operation h
Operation
dT
Power
Energy
SD card
Temperatures
T1
 Flow (l/min)
GDS1"Sensor choice"
GDS2 "Sensor choice"
T6
 Liter/Impulse
T1- T5
 Calibration (Pt-1000)
Adjustments
Energy
Adjustments
Overheat temp
Max temp
Min temp
Freeze Temp
T2
T3
T4
T5

MAIN CHARACTERISTICS

- Large graphic display with backlight
- Easy use interface (4 keys with scroll menu).
- Several languages available
- SD card interface to save the recorded statistics
(Temperatures, Power, Energy, Time operation...) and
parameters.
- 2 energy counters (1 for solar energy and 1 free to specify).
- 1 Bus connection (RJ45) for Extension module (MULTIPLEX)
and communication option.
- Graphic view for Temperature, power, energy...
- 8 working systems with several extra functions possibility
- 5 Inputs for temperature sensors (PT1000 type)
- 1 Logical Input for Impulse flow meter input (for energy
measurement).
- 2 Analogue inputs for Grundfos direct sensors (Flow,
Pressure and temperature sensor)
- 2 electronics outputs for pump (Standard or PWM) with pump
exercise function.
- 1 standard output for Extra function (to control additional
heat, cooling system...)
- Automatic, Off, Manual test mode and chimney sweep
function.
- Sensors Auto checks (Short circuit and breaks)
- Collector protection (Freeze and overheat)
- Permanent memory storage

TECHNICAL CHARACTERISTICS

Operating temperature
Electrical Protection
Installation Category
Pollution Degree
Fusible
Power supply
Maximum Power
Consumption
(with all outputs activated)
Outputs:
P1 (Main pump with standard
or PWM speed regulation):
P2 (Pump with standard or
PWM speed regulation, valve):
P3 (Extra, Additional heat,
cooling...)
Inputs:
T1 (Collector1):
T2 (Tank1):
T3 (Extra sensor):
T4 (Extra sensor, Tank2,
Collector2):
T5 (Collector return):
T6 (Flow meter):
GDS1 & GDS2 (Grundfos
sensor):
Flow or pressure.
Sensors delivered with the
product:
2 Collectors sensor (red)
1 Tank (grey)
1 Extra (grey)
Software version
3
0°C – 50°C
IP20
CLASS I
2
5AType Fuse 230Vac
(5x20mm)
230Vac +/- 10% 50Hz
4,7A (~ 1080W)
Triac max. 1A 230VAC.
Minimum power switching
>1W
Triac max. 1A 230VAC.
Minimum power switching
>1W
Relay max. 2A 230VAC
* Higher power
consumption: only possible
with external power relay
PT 1000 type
PT 1000 type
PT 1000 type
PT 1000 type
PT 1000 type
Impulse type (low voltage
5V)
Analogue type
(Grundfos VFS, RPS)
PT1000 (1.5M 180°C)
PT1000 (3M 105°C)
PT1000 (3M 105°C )
Displayed during
initialisation
Higher Version 11xx

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis