7 Troubleshooting

7.1 Replacing the fuse

Maintenance must only be performed on
the rack when the power is disconnected
and with the disconnecting device open.
A 1.25A, 250Vac slow blow fuse is found on the rear
panel of the rack power supply.
If the power supply fails to go on, verify the
continuity of the fuse (Fig. 1, page 4).
8 Disposal of waste
materials
This symbol mark and recycle system
are applied only to EU countries and not
applied to the countries in the other area of
the world.
Your product is designed and manufactured with
high quality materials and components which can be
recycled and reused.
This symbol means that electrical and electronic
equipment, at their end-of-life, should be disposed of
separately from your household waste.
Please dispose of this equipment at your local
Community waste collection or Recycling centre.
In the European Union there are separate collection
systems for used electrical and electronic products.

9 Technical data

9.1 General

Supplied with power cable with plug for EU, UK, USA
markets

9.2 Mechanical

Dimensions (WxHxL): 190x175x482mm
Slots available: 14

9.3 Electrical

Vin: 90-264Vac, 70W Max.
Vout: 9Vdc

9.4 Environment

Indoor
Operating temperature: -40°C/+75°C
Heat supplied: 254kJ (240BTU)
5