Electrical connections should be made as shown in the
wiring diagram.
Mount the backing plate. Use only the round holes.
The thermostat can now be filled into the wall box.
screw back frame and cover;
put back the temperature control knob (A).
3. MouNTING of fLooR SENSoR
Place the floor sensor in an approved non conductive
installation pipe in accordance with EN 61386-1, which is
embedded in the floor
placed in the concrete layer as close as possible to the
surface. The installation pipe must be centred between the
heating cable loops. Sensor cable can be extended by up to
100 m by means of a separate cable.
4. SETbACK TEMpERATuRE
Setback of temperature setting is activated by a 230 V (L)
signal from an external time switch to terminal 5. Setback
temperature is fixed 5˚C.
2).
(fig.
3). The pipe end is sealed and
(fig.
6