The filters clog up over time and need to be replaced regularly.
W
With contamination display AS: red marking indicates when
the filter should be replaced.
W
Without contamination display AS: in case of active carbon
filters, every six months, all other filters annually. However,
this is only approximate, because intervals depend on the
quality of compressed air and flow rate.
Please use the material numbers listed below to order.
The addresses of the international agencies are available at
www.aventics.com/contact.
Wearing parts
4
b
Filter elements, 5 μm
b
Filter elements, 25 μm
b
Filter elements, 40 μm
b
Pre-filter elements, 0.3 μm
c
Micro-filter elements,
0.01 μm
c
Active carbon
filter elements
a
Filter end piece
Replace filter element:
AS1
FLS/FLP/FLC/FLA
5
1. Unscrew the reservoir
from the housing (a, b).
2. Remove the filter seat
(c, d).
3. Remove the top twist cap.
4. Replace the filter
insert (e).
5. Replace the twist cap in the correct
position.
6. Ensure that the o-ring
is there to seal the
reservoir.
Mat. numbers
W
AS1/AS2: 182920706
W
AS3: 1829207068
W
AS5: R961403328
W
AS1/AS2: R961400004
W
AS3: R961400005
W
AS5: R961400006
W
AS1/AS2: R961400009
W
AS3: R961400142
W
AS5: R961403332
W
AS1/AS2: 1829207047
W
AS3: R961400140
W
AS5: R961403330
W
AS1/AS2: R961400027
W
AS3: R961400141
W
AS5: R961403331
W
AS1/AS2: 1829207044
W
AS3: R961400143
W
AS5: R961403333
W
AS1/AS2: 1827009612
W
AS3: R961400139
W
AS5: R961403329
AS2 – AS5
FLS/FLP
FLC/FLA
6
7
Pull down the unlocking device (a),
turn the reservoir (b) in an anti-
clockwise direction and then pull
it down and remove (c).
Remove the filter
Remove the
seat (d, e).
filter piece
(d, e).
Replace the filter insert (f).
FLS/FLP/FLC/FLA
5
7. Screw in the filter
insert (f) and tighten
gently by hand (g).
8. Screw in the reservoir
as far as it will go in
a clockwise direction
(h, i).
7
Decommissioning, Disassembly,
Replacement
Danger of injury in case of disassembly or replacement under
pressure or voltage
Disassembling when under pressure or electrical voltage
may lead to injuries and damage to the product or system
components.
O
Make sure that the relevant system part is not under voltage
or pressure before you disassemble the product or replace
parts.
O
Protect the system against being switched on.
8
Disposal
Dispose of the product and condensate in accordance with
the national regulations in your country.
9

Conversion and Extension

Mounting contamination display AS
(FLP/FLC)
1. Release the screws (b) on the filter housing (a) and remove
the cover (c).
2. Insert four 1.5 seals to DIN 3771 (d).
Place the contamination display (e) on the filter housing
and tighten the screws (f).
Max. tightening torque: 1.5 Nm, M5 x 20 to DIN 965
Change flow direction (AS2 – AS5)
No conversion is necessary on the AS1 series. The "right/
left flow" version has a separate order number.
Filter conversion
On all components, the flow direction change is performed by
rotating mounting by 180° around the vertical axis. The housing
covers need to be changed for the purpose.
1. Release the housing cover at the front and back.
2. Re-attach the covers at the opposite sides with the cover
bearing the AVENTICS logo facing to the front.
AS1
FLS/FLP
6
Screw in the new filter insert (g)
and tighten gently by hand (h).
Mount the reservoir offset by
45° (i) and turn in a clockwise
direction until you hear the
unlocking device click into
place (j).