Herunterladen Inhalt Inhalt Diese Seite drucken

Interlogix TX-6310-03-1 Bedienungsanleitung Seite 9

Vorschau ausblenden Andere Handbücher für TX-6310-03-1:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Operation characteristics
LED display
Normal
Green Power
operation
LED flashes
every 30 s.
Carbon
Red Alarm LED
monoxide
flashes with
alarm
beeps.
Low battery /
Red Alarm LED
low battery
flashes every
hush
60 s.
Alarm end-of-
Red Alarm LED
life indicator
flashes two
times every
30 s.
Trouble /
Red Alarm LED
service alarm
flashes every
30 s.
Error
Red Alarm LED
condition
constantly on.
Test mode
Red Alarm LED
flashes with
beeps.
Tamper
Red Alarm LED
flashes every
30 s.
P/N 3102145 (ML) • REV F • ISS 11MAR19
Alarm sound
Unit status
None.
Normal DC
operation (sensing
no CO) and with
good batteries.
Four quick beeps,
Alarm condition.
5 s silence,
Dangerous
repeating.
concentrations of
CO detected.
One quick beep
Batteries need to
every 60 s.
be replaced.
Two quick beeps
End of CO alarm
every 30 s.
life.
One quick beep
Unit is in trouble
every 30 s.
condition.
Constant alarm.
Very low battery or
unit malfunction.
Four quick beeps,
Normal operation
5 seconds
when Test/Hush
silence, repeated
button is pressed.
once.
One quick beep
Unit is in tamper
every 30 s.
condition.
Control panel status
Recommendation
Normal operating
None.
condition.
See "Emergency Actions" on page 6.
Alarm condition.
Replace all three AA batteries.
Trouble condition,
trouble beeps every
Press Test/Hush button and release. This
60 s.
will silence the low battery audible chirp
between 8 and 11 hours allowing for a more
convenient time to replace the batteries.
Trouble condition,
Press the Test/Hush button and release.
trouble beeps every
This will silence the end-of-life signal for up
60 s.
to three days. After three days, the unit will
resume end-of-life chirps. Hush mode will
silence the alarm ten times or up to
30 days. After 30 days, the unit can no
longer be hushed. Replace the CO alarm
immediately. The unit will not respond to
CO.
Trouble condition,
Replace batteries. If condition continues,
trouble beeps every
unit has malfunctioned. Replace
60 s.
immediately. Unit will not respond to CO.
Trouble condition,
Replace batteries. If condition continues,
trouble beeps every
unit has malfunctioned. Replace
60 s.
immediately. Unit will not respond to CO.
Sensor test mode
CO not detected. Alarm for test purposes
only.
Trouble condition,
Place alarm body back onto mounting plate.
trouble beeps every
If condition continues, unit has
60 s.
malfunctioned. Replace immediately.
9 / 25

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis