In case of incorrect installation or connection, the warranty becomes invalid.
Any change to the appliance, including replacement of the mains cable, must be performed by a certified
installer.

UNPACKING

1.
Remove the packaging.
2.
Examine the appliance for damage.
3.
Make sure that the voltage is the same as on the type plate.

PREPARING FOR INSTALLATION

1.
Make sure that there is sufficient space available around the appliance.
2.
Make sure that the worktop is prepared according to the dimensions of the appliance (A).
Note:
Use dimensions B, if the appliance must be flush with the worktop.
MAKING VENTILATION OPENINGS
The electronics in the appliance require cooling. The appliance will automatically switch off when there is insufficient
ventilation.
Caution:
Do not block the ventilation openings of the appliance.
Using an intermediate support
Warning:
When the appliance is installed above a drawer, metal objects in the drawer may become hot. Use an
intermediate support to prevent this.
1.
Install the intermediate support above the drawer. Use dimensions A of Figure 6.
Making the openings
1.
Make an opening of 100 cm
2.
Make an opening at the rear of the kitchen unit. Use the appliance width and a height of 20
mm.
3.
Make sure that there is a space of 30 mm between the appliance and the oven, drawer or
intermediate support. Refer to Figure 9 and 10.
4.
Make sure that the worktop has a minimum thickness of 38 mm. Refer to Figure 9 and 10.

CONNECTING THE APPLIANCE

The appliance is supplied with a mains cable and uses a 5-pin Perilex plug (not included).
1.
Make sure that the electrical system is suitable for the load of the appliance.
2.
Make sure that the mains socket is grounded.
3.
Connect the appliance according to the wiring diagram in Figure 11 or 12.
Warning:
Connecting according to the wiring diagrams may only be performed by a certified installer.
30
EN
2
at the bottom of the kitchen unit.
(Figure 4)
(Figure 5)
(Figure 6)
(Figure 7)
(Figure 8)
(Figure 9)
(Figure 10)
(Figure 11)
(Figure 12)