Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

12

13. Technical data

Operating voltage U_b
Battery lifetime
Current consumption:
Frequency band
Transmitting range
Range (programmable)
Area optics
Long range optics (Item no. 033435)
Curtain optics (Item no. 033434)
PIR sensor
PIR sensivity (programmable)
Installation position
Protection class as per EN 60529
Environmental class as per VdS
Operating temperature range
Storage temperatur range
- without battery pack
- with battery pack
Dimensions W x H x D
Colour
*Battery lifetime depends on actuations per day:
typ. 2.5 years at 8 hours actuation per day
typ. 3.0 years at 1 hour actuation per day
typ. 2.0 years at 24 hours actuation per day.
The detector Viewguard PIR RF, Item no. 015610.01
when used as intended, comply with the basic require-
ments of article 3 of the R&TTE Guideline 1999/5/EG.
The EU conformity declaration can be downloaded at
"www.honeywell.com/security/de" under Service- /
Download.
14. Warnings about lithium batteries
The device contains a lithium battery. To avoid the risk of fire or burns,
the battery must not be damaged, short-circuited or reloaded. Do not
contact it with fire or water. There is a risk of explosion if the battery is
changed improperly. Replace the battery only by the same or an
equivalent type recommended by the manufacturer. D i s p o s e u s e d
batteries according to EU guideline 2006/66/EG (see following text).
A battery change must only be carried out by qualified personell
introduced to the VDE regulations.
Notes on environment / disposal
Batteries and recharchable batteries - even free from heavy metal -
must not disposed of in domestic waste. According to EU guideline
2006/66/EG users are obligated to return batteries for recycling. In
Germany they will be accepted for free at each selling point;
alternatively they can be dispensed in public storage vessels for old
batteries or at public waste disposal authorities.
Outside of Germany please observe the local regulations on battery
disposal.
Commercial batteries may contain heavy metal labelled by:
Pb for lead
Cd for cadmium
Hg for mercury
Pb
Honeywell Security Group
Novar GmbH
Johannes-Mauthe-Straße 14
D-72458 Albstadt
www.honeywell.com/security/de
1 Batteriepack 7,2 V/2,6 Ah
Item no. 015605
typ. 2,5 years*
typ. 65 µA
433 / 868 MHz
typ. 300 m
by free visibility
8 / 11 / 13 / 15 m
29 / 35 / 42 / 50 m
17 / 21 / 25 / 30 m
temperature-compensated
normal / high
vertical, optics at bottom
IP 30
II
-10 °C bis +55 °C
-25 °C up to +70 °C
25 °C +/- 10 °C
64 x 158 x 48 mm
traffic
white (similar to RAL 9016)
Cd
Hg
Mounting and Connection Instructions Viewguard PIR RF
15. Accessories
15.1 Mounting accessories
033390.17 Adjustable joint
Swivel range: Horizontal
not as per VdS and EN
033588.17 Ball-and socket set for wall and corner mounting
Swivel range: Horizontal
not as per VdS and EN
033391.17 Seal
(PU = 20 piece)
15.2 Viewguard PIR mirror sets
033434
Viewguard PIR mirror, Curtain optics
(PU = 3 piece)
The curtain mirror is suitable for monitoring possible intrusion locations.
mirror distribution 11 zones on 11 levels
acceptance angle 7.5° hor., 85° vert.
range
Mounting height:
- Recommended:
- Permitted:
Horizontal detection coverage
0.5m
0.5m
0
5m
Vertical detection coverage, mounting height 2.50 m
Vertical inclination 0°
2.5m
5m
033435
Viewguard PIR mirror, Long-range optics
(PU = 3 piece)
The long-range mirror is suitable for monitoring corridors.
mirror distribution 8 zones on 6 levels
acceptance angle 30° hor., 78° vert.
range
Mounting height:
- Recommended:
- Permitted:
Horizontal detection coverage
1.5m
0
1.5m
0
10m
Vertical detection coverage
Vertical inclination 0°
2.5m
0
10m
16. VdS approval
015610.01 Viewguard PIR RF
G108506, IDS Class B, with area mirror
G108507, IDS Class B, retrofitted with longe-range mirror
G108508, IDS Class B, retrofitted with curtain mirror
P02647-10-002-03
2014-09-22
© 2014 Novar GmbH
±20°,
vertical +4° up to -8°
±45°,
vertical
±20°
17 / 21 / 25 / 30 m
2.50 m for optimal operating sensitivity.
2.20 m to 3.00 m
10m
15m
20m
10m
15m
20m
29 / 35 / 42 / 50 m
2.50 m for optimal operating sensitivity.
2.20 m to 3.00 m
20m
30m
20m
30m
25m
30m
25m
30m
40m
50m
40m
50m

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis