Herunterladen Diese Seite drucken

When An Abnormality Is Detected While Charging - Sony AC-DN10 Handbuch

Netzadapter

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 49
About the charging indicator
The charging indicator shows the charging status of the
attached battery pack as shown in the table below.
Indicator status
Flashing (orange)
Flashing (green)
On (green)
Flashing rapidly
(orange and green)

When an abnormality is detected while charging

When one of the following conditions is detected while
charging, the charging indicator flashes rapidly in orange and
green and the charging is cancelled to protect the battery pack.
• After the start of charging, the voltage of the DC output
connector for battery charging has dropped below the
specified level (6 V).
• After the start of charging, the voltage of the DC output
connector for battery charging has exceeded the specified
level (17.5 V).
• The battery voltage did not rise to the specified level within a
specified period (2 hours).
The charging indicator remains flashing until the AC-DN10 is
disconnected from the AC power source or the battery pack is
removed.
Notes
• When a battery pack which is not chargeable with the AC-
DN10 is connected, the charging does not take place and the
charging indicator does not light up.
• The BP-M50/M100 Nickel Metal Hydride Battery Packs
cannot be charged with the AC-DN10.
Charging status
In progress (less than 95% of the full
capacity)
In progress (95% or more to less than
100% of the full capacity)
Fully charged
An abnormality is detected. (For details
see "When an abnormality is detected
while charging" below.)
13 (E)