Herunterladen Inhalt Inhalt Diese Seite drucken

Lake People ADC F444 Bedienungsanleitung Seite 16

2-ch, 4-ch analog-digital converter; 2/2-ch a/d – d/a converter; 2-ch, 4-ch digital-analog converter
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Connection / Connectors for Analog Signals
ANALOG SIGNALS
HOT
COLD
SHIELD
BALANCED INCOMING SIGNAL
ANALOG SIGNALS
XLR FEMALE PLUG
HOT
COLD
SHIELD
BALANCED OUTGOING SIGNAL
ANALOG SIGNALS
HOT
GND
SHIELD
BALANCED INCOMING SIGNAL
2-wire cable should be prefered !!
ANALOG SIGNALS
XLR FEMALE PLUG
HOT
GND
SHIELD
BALANCED OUTGOING SIGNAL
2-wire cable should be prefered !!
ANALOG SIGNALS
XLR FEMALE PLUG
HOT
GND
SHIELD
BALANCED OUTGOING SIGNAL
2-wire cable should be prefered !!
ANALOG SIGNALS
HOT
GND
SHIELD
UNBALANCED INCOMING SIGNAL
16
Balanced Cable (Signal) to (Transformer) Balanced Input
XLR MALE PLUG
2
3
X
2
3
X
Unbalanced Cable (Signal) to (Transformer) Balanced Input
XLR MALE PLUG
2
3
?
X
2
3
?
X
2
3
X
CINCH/BNC PLUG
Shield = Signal Ground = Pin 1
1
Hot / + Phase = Pin 2
Cold / - Phase = Pin 3
The case of the connector should not be wired
to the shield of the cable. The connector is routed
to earth potential (PE) when plugged into the
corresponding socket of the case !
(Transformer) Balanced Output to Balanced Cable
Shield = Signal Ground = Pin 1
1
Hot / + Phase = Pin 2
Cold / - Phase = Pin 3
The case of the connector should not be wired
to the shield of the cable. The connector is routed
to earth potential (PE) when plugged into the
corresponding socket of the case !
Shield = Signal Ground = Pin 1
1
Hot / Signal = Pin 2
Cold / Ground = Pin 3
The case of the connector should not be wired
to the shield of the cable. The connector is routed
to earth potential (PE) when plugged into the
corresponding socket of the case !
Transformer Balanced Output to Unbalanced Cable
Shield = Signal Ground = Pin 1
1
Hot / Signal = Pin 2
Cold / Ground = Pin 3
The case of the connector should not be wired
to the shield of the cable. The connector is routed
to earth potential (PE) when plugged into the
corresponding socket of the case !
Electronically Balanced Output to Unbalanced Cable
Shield = Signal Ground = Pin 1
1
Hot / Signal = Pin 2
(Cold) = Pin 3 = must be left open !!
The case of the connector should not be wired
to the shield of the cable. The connector is routed
to earth potential (PE) when plugged into the
corresponding socket of the case !
Unbalanced Input / Output to Unbalanced Cable
HOT
GND
SHIELD
UNBALANCED OUTGOING SIGNAL
CINCH/BNC PLUG

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis