Herunterladen Inhalt Inhalt Diese Seite drucken

Info; Installation Procedure; Of The Electronic Control Panel; Electrical Connections - Jacuzzi MOOD S Vorinstallationsblatt

Vorschau ausblenden Andere Handbücher für MOOD S:
Inhaltsverzeichnis

Werbung

Info

As soon as you receive the product, check that it is in perfect
condition and if not, immediately notify the forwarding agent.
Note for custom models
The sizes and fittings for custom models are defined during
the design stage, in line with the Jacuzzi® sales documentation.
For information regarding the electrics and plumbing, please
see below and refer to the technical characteristics tables for
each configuration (S, M, L and XL).

Installation procedure

ATTENTION: this equipment may not be installed
outdoors.
Any installation types/methods which differ from those
specified must be assessed on an individual basis and must
comply, without fail, to the indicated provisions.
The following installation types are supported (refer also to the
relevant instructions):
CORNER (ref. "c").
WALL MOUNTED (ref. "m")
with the second wall finished (optional).
RECESS (ref. "n")
the "corner" model can also be installed between two walls (by the
customer), leaving the spaces necessary for ventilation.
ATTENTION: there must be a free space between the
walls and the sauna (see drawings, ref. A): this is nec-
essary for suitable ventilation. Ventilation must al-
ways be provided!
If you wish to install a panel to close off the front area
of the appliance (between the roof and the ceiling),
you must ensure adequate ventilation, as instructed;
in addition, you must ensure that the entire panel is
completely removable for inspection and/or subse-
quent maintenance operations of the components
present on the roof of the appliance.
The installation area must comply with the following characteristics:
- Optimal room temperature: approximately 22-25 °C
- Room height: sauna height + 20 cm min.
- Floor: level.
The flooring must not be plastic or carpeted.
Preparatory work for remote installation of the
electronic control panel
The electronic control panel can be installed remotely, away
from the sauna, in a position chosen by the customer. To do this:
- prepare a duct for the cable connecting the electronic control
box on the sauna to the control panel (the cable is 10 m long).
- make a hollow cavity in the chosen wall to install the panel (see
figure):
min 8 mm÷30 mm
a
(*)
> 30 mm
20
mm
5
a
mm
a
127
mm
130
mm
(*): in dotazione / supplied / fourni / inbegriffen / incluido / включены
The temperature of the wall where the electronic panel will be
installed must not exceed 75°C.

Electrical connections

The electrical connection can be made in one of the following ways:
"Mood S/M"
- single-phase line (220-240V 1~) or three-phase line con-
sisting of three phase conductors + neutral conductor (380-
415V 3N~).
"Mood S/M/L/XL"
- three-phase line consisting of three phase conductors +
neutral conductor (380-415V 3N~).
The rated power supply voltage of the equipment is al-
ways 220-240V.
The equipment can also be installed in countries where
the 220-240V voltage is supplied by a two-phase system
(MOOD S/MOOD M); for the connection please refer to the
instruction manual.
To connect the building's electrical system, you must use a
cable protected with a sheath with characteristics not inferior to
H 07 RN-F, as indicated in position 2/2a and that has the follow-
ing cross-section:
power
kW
number of conductors x conductor cross section (mm
3
4.5
6
7.5
15
120 ± 0,5
mm
a
a
L = 10 m MAX
single-phase
three-phase
(220-240V)
(380-415V)
3x2.5
3x4
-
-
117 ± 0,5
mm
2
)
5x2.5
5x2.5
5x2.5
5x2.5

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Mood mMood lMood xl

Inhaltsverzeichnis