Connection to the power supply
The Electrolux cooking hob comes with a 3-core power cable with free terminals
If the hob is permanently connected to the power supply, install a circuit breaker having a contact opening distance that
allows complete disconnection in the conditions of overvoltage category III. Make sure:
a) the plug and socket are suitable for a 16 A current;
b) both are easily reached and positioned so that no live part can be accessed when
inserting or removing the plug;
c) the plug can be inserted without difficulty and is accessible with the appliance installed;
d) the hob does not rest against the plug when installed in the cabinet;
e) the terminals of two appliances are not connected to the same plug;
2
f) a 3x 0.5 mm
H05VV-F type cable is used when replacing the power cable;
g) to respect the polarities of the free terminals
(Brown=Line Blue=Neutral Yellow/Green=Earth).
NB: Make sure the characteristics of your household electrical system (voltage, max. power and current) are compatible
with those of your Electrolux hob.
Replacing injectors
NB: All the products are factory-set for natural gas (G20).
If a different type of gas is to be used, change the injectors as follows:
1. remove the grates, burner caps and flame-spreaders;
2. unscrew and remove the injectors and replace them with those supplied, corresponding to the mains gas, making
sure the marking is that given in the table (page 17);
3. refit the flame-spreaders, burner caps and grates;
4. these burners do not require air adjustment.
Important
When converting the appliance to a different type of gas, place the corresponding sticker (supplied as an accessory)
in the special space on the dataplate. For operation with LPG. (G30 or G31) the minimum adjustment screw must be
screwed down. These appliances are supplied in cat. II 2H3+.
Minimum flame adjustment
– Remove the knobs (push-on type).
– Light the burners and adjust the minimum flame by turning the adjustment
screw clockwise to decrease the flame and anticlockwise to increase it
(fig. 6). The screwdriver for adjustment is supplied with the accessories.
16
BLUE
YELLOW/GREEN
BROWN
Highest minimum
adjustment
Lowest
minimum
adjustment
fig. 6