Herunterladen Inhalt Inhalt Diese Seite drucken

ATTACK AK series Bedienungsanleitung Seite 151

Inhaltsverzeichnis

Werbung

DESCRiPTiON
ATTACK S – is based on the ATTACK AK type. Disk and stratified pipe in-
stalled in the exchanger enable creation of water layers according to the
temperature. This construction ensures different temperature layers at
the inlets and outlets.
ATTACK SS – is based on the ATTACK AS and the ATTACK S  types. It is
accessorized with an extra exchanger for connection to the solar circuit.
ATTACK S: 10× socket G 1 ½", 5× socket G ½"
ATTACK SS: 10× socket G 1 ½", 5× socket G ½", 2× socket G 1" – solar circuit
KEy FOR THE ACCUMULATiON TANKS
1 – Flow connection – boiler . . . . . . . . . . . 1 ½"
2 – Freely disposable . . . . . . . . . . . . . . . . 1 ½"
3 – Electrical heating coil (EL) . . . . . . . . . . 1 ½"
4 – Freely disposable . . . . . . . . . . . . . . . . 1 ½"
5 – Return connection – heating circuit . . . . 1 ½"
6 – Flow connection – heating circuit (radiators) 1 ½"
7 – Flow connection – heating circuit (floor) . 1 ½"
8 – Return connection, gas, oil or pellet boiler 1 ½"
TECHNiCAL PARAMETERS
S500K
C 1 405 1 013 871
S800K
- 1 545 1 135 946 840 725 315 491 1 340 -
S1000K
- 1 735 1 255 1 036 840 775 295 577 1 495
S1250K
- 1 655 1 175 988 1 000 695 285 565 1 415
S1500K
- 1 755 1 345 1 072 1 050 820 375 653 1 545 -
S2000K
- 1 955 1 408 1 314 1 150 862 315 685 1 682 -
SS500K
C 1 405 1 013 871
SS800K
- 1 545 1 135 946 840 725 315 491 1 340 315 725 790 990 1 842 1 892 1 898 95 105 3
SS1000K - 1 735 1 255 1 036 840 775 295 577 1 495 295 860 790 990 2 031 2 082 2 081 95 121 3
SS1250K - 1 655 1 175 988 1 000 695 285 565 1 415 285 850 950 1 150 1 975 2 025 2 064 95 142 3
SS1500K - 1 755 1 345 1 072 1 050 820 375 653 1 545 375 895 1 000 1 200 2 100 2 150 2 160 95 161 3
SS2000K - 1 955 1 408 1 314 1 150 862 315 685 1 682 315 665 1 100 1 300 2 309 2 356 2 390 95 188 3
Tank
700 621 230 461 1 209 -
-
-
700 621 230 461 1 209 230 710 650
9 – Return connection – wood boiler . . . . . 1 ½"
10 – Sensor of solar system or heating . . . . . . ½"
AS – Flow connection of solar system . . . . . . . 1"
RS – Return connection of solar system . . . . . . 1"
SF – Upper solar sensor . . . . . . . . . . . . . . . . ½"
SU – Bottom solar sensor . . . . . . . . . . . . . . . ½"
D1 – Diameter without insulation
D2 – Diameter with insulation
-
650
850 1 680 1 730 1 698 95
-
790 990 1 842 1 892 1 898 95 105 3
-
790 990 2 031 2 082 2 081 95 121 3
-
950 1 150 1 975 2 025 2 064 95 142 3
- 1 000 1 200 2 100 2 150 2 160 95 161 3
- 1 100 1 300 2 309 2 356 2 390 95 188 3
850 1 680 1 730 1 698 95
ACCUMULATION TANKS
Solar
Tank
exchanger
-
3
-
-
-
488 102
-
-
-
713 132
-
-
-
891 141
-
-
-
1 239 186
-
-
-
1 420 232
-
-
-
1 960 330
-
3
1,8 11,9 10
488 139
2,4 15,9 10
713 173
3
19,8 10
891 197
3
19,8 10 1 239 243
3,6 23,7 10 1 420 296
4,2 27,7 10 1 960 330
13

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis