DESCRiPTiON
The accumulation tanks ATTACK TUV, TUVS are made from a quality steel and
they serve for accumulation of the heating water as well as for the D.H.W. pre-
paration in a water coil. The ATTACK TUVS model is accessorized with an extra
exchanger for connection to the solar system.
ATTACK TUV: 9× socket G 1 ½", 5× socket G ½", 2× socket G 1" – D.H.W.
ATTACK TUVS: 9× socket G 1 ½", 5× socket G ½", 2× socket G 1" – solar circuit,
2× socket G 1 1/4" – D.H.W.
KEy FOR THE ACCUMULATiON TANKS
1 – Flow connection - boiler . . . . . . . . . . . . . 1 ½"
2 – Freely disposable . . . . . . . . . . . . . . . . . . 1 ½"
3 – Electrical heating coil (EL) . . . . . . . . . . . . 1 ½"
4 – Freely disposable . . . . . . . . . . . . . . . . . . 1 ½"
5 – Return connection – heating circuit . . . . . . 1 ½"
6 – Flow connection – heating circuit (radiators) . 1 ½"
7 – Flow connection – heating circuit (floor) . . . 1 ½"
8 – Return connection – gas, oil or pellet boiler . 1 ½"
TECHNiCAL PARAMETERS
TUV500K
C 1 405 1 013 771 600 621 230 -
TUV600K
- 1 515 1 123 794 650 684 245 -
TUV800K
- 1 545 1 135 846 735 725 315 -
TUV1000K
- 1 735 1 255 1 036 735 775 295 -
TUV1250K
- 1 655 1 175 988 880 695 285 -
TUV1500K
- 1 755 1 345 1 072 920 820 375 -
TUV2000K
- 1 955 1 408 1 314 1 000 862 315 -
TUVS500K
C 1 405 1 013 771 600 621 230 230 710 650 850 1 631 1 717 1 831 95
TUVS600K
- 1 515 1 123 794 650 684 245 245 725 700 900 1 754 1 841 1 954 95
TUVS800K
- 1 545 1 135 846 735 725 315 315 725 790 990 1 806 1 898 2 006 95 105
TUVS1000K
- 1 735 1 255 1 036 735 775 295 295 860 790 990 1 996 2 081 2 196 95 121
TUVS1250K
- 1 655 1 175 988 880 695 285 285 850 950 1 150 1 948 2 064 2 148 95 142
TUVS1500K
- 1 755 1 345 1 072 920 820 375 375 895 1 000 1 200 2 032 2 160 2 232 95 161
TUVS2000K
- 1 955 1 408 1 314 1 000 862 315 315 843 1 100 1 300 2 274 2 390 2 474 95 188
9 – Return connection – wood boiler . . . . . . . 1 ½"
10 – Sensor of solar system or heating . . . . . . . ½"
AS – Flow connection of solar system . . . . . . . . 1"
RS – Return connection of solar system . . . . . . . 1"
D1 – Diameter without insulation
D2 – Diameter with insulation
AF – Cold drinking water . . . . . . . . . . . . . . . 1 1/4"
AC – Domestic hot water . . . . . . . . . . . . . . . 1 1/4"
Tank
-
650 850 1 631 1 717 1 831 95
-
700 900 1 754 1 841 1 954 95
-
790 990 1 806 1 898 2 006 95 105
-
790 990 1 996 2 081 2 196 95 121
-
950 1 150 1 948 2 064 2 148 95 142
- 1 000 1 200 2 032 2 160 2 232 95 161
- 1 100 1 300 2 274 2 390 2 474 95 188
ACCUMULATION TANKS
Solar
exchanger
-
3
-
-
-
-
99
3
-
-
-
-
3
-
-
-
-
3
-
-
-
-
3
-
-
-
-
3
-
-
-
-
3
-
-
-
-
-
3
1,8 11,9 10
110 6,25 474 220
99
3
1,8 11,9 10
110 6,25 605 232
3
2,4 15,9 10
110 6,25 713 244
3
3 19,8 10
110 6,25 891 274
3
3 19,8 10
110 6,25 1 239 313
3
3,6 19,8 10
110 6,25 1 420 362
3
4,2 23,7 10
110 6,25 1 960 394
Tank
6,25 474 183
6,25 605 194
6,25 713 209
6,25 891 218
6,25 1 239 257
6,25 1 420 298
6,25 1 960 333
11