Herunterladen Inhalt Inhalt Diese Seite drucken

ATTACK AK series Bedienungsanleitung Seite 145

Inhaltsverzeichnis

Werbung

DESCRiPTiON
The accumulation tanks ATTACK AK, AS made from the quality steel serve for accu-
mulation and subsequent distribution of the heat energy from the biomass boiler
(e.g. SLX, DPX, DP, PELLET 30 AUTOMATiC Plus, WOOD&PELLET). The ATTACK AS
model is accessorized with an extra exchanger to be connected to the solar system.
ATTACK AK: 9× socket G 1 ½", 4× socket G ½"
ATTACK AS: 9× socket G 1 ½", 4× socket G ½", 2× socket G 1" – solar circuit
KEy FOR THE ACCUMULATiON TANKS
1 – Flow connection – boiler . . . . . . . . . . . . . 1 ½"
2 – Freely disposable . . . . . . . . . . . . . . . . . . 1 ½"
3 – Freely disposable . . . . . . . . . . . . . . . . . . 1 ½"
4 – Return connection – heating circuit . . . . . . 1 ½"
5 – Flow connection – heating circuit (radiators) . 1 ½"
6 – Flow connection – heating circuit (floor) . . . 1 ½"
TECHNiCAL PARAMETERS
AK200K
C
925
705
455 205
AK300K
C 1 110
790
460 210
AK400K
C 1 120
815
515
AK500K
C 1 405 1 013 621 230
AK800K
- 1 545 1 135 725
AK1000K
- 1 735 1 255 775 295
AK1500K
- 1 755 1 345 820 375
AK2000K - 1 955 1 409 862
AK2500K
- 2 005 1 465 915
AK3000K - 2 205 1 600 985 375
AK4000K - 2 385 1 730 1 065 405
AK5000K - 2 285 1 680 1 065 455
AS200K
C
925
705
455 205 205
AS300K
C 1 110
790
460 210
AS400K
C 1 120
815
515
AS500K
C 1 405 1 013 621 230 230
AS800K
- 1 545 1 135 725
AS1000K
- 1 735 1 255 775 295 295 860
AS1500K
- 1 755 1 345 820 375
AS2000K
- 1 955 1 409 862
AS2500K
- 2 005 1 465 915
AS3000K
- 2 205 1 600 985 375
AS4000K
- 2 385 1 730 1 065 405 405 1 125 1 450 1 400 1 600 2 819 2 869 2 872
AS5000K
- 2 285 1 680 1 065 455
Tank
-
-
550
500
-
-
600
550
210
-
-
700
650
-
-
700
650
315
-
-
840
790
-
-
840
790
-
-
1 050 1 000 1 200 2 095 2 145 2 142
315
-
-
1 150 1 100 1 300 2 310 2 360 2 353
375
-
-
1 250 1 200 1 400 2 387 2 437 2 438
-
-
1 300 1 250 1 450 2 596 2 646 2 643
-
-
1 450 1 400 1 600 2 819 2 869 2 872
-
-
1 650 1 600 1 800 2 770 2 820 2 845
545
550
500
210
610
600
550
210
210
610
700
650
710
700
650
315
315
725
840
790
840
790
375
895 1 050 1 000 1 200 2 095 2 145 2 142
315
315
843 1 150 1 100 1 300 2 310 2 360 2 353
375
375 1 095 1 250 1 200 1 400 2 387 2 437 2 438
375 1 095 1 300 1 250 1 450 2 596 2 646 2 643
455 1 175 1 650 1 600 1 800 2 770 2 820 2 845
7 – Return connection – gas, oil and pellet boiler . . 1 ½"
8 – Return connection – wood boiler . . . . . . . 1 ½"
9 – Sensor of solar system or heating . . . . . . . . ½"
AS – Flow connection of solar system . . . . . . . . 1"
RS – Return connection of solar system . . . . . . . 1"
D1 – Diameter without insulation
D2 – Diameter with insulation
700
1 140 1 190 1 157
3
750
1 350 1 400 1 368
3
850
1 380 1 430 1 402
3
850
1 660 1 710 1 678
3
990
1 840 1 890 1 864
3
990
2 030 2 080 2 052
3
3
3
3
3
3
3
700
1 140 1 190 1 157
3
750
1 350 1 400 1 368
3
850
1 380 1 430 1 402
3
850
1 660 1 710 1 678
3
990
1 840 1 890 1 864
3
990
2 030 2 080 2 052
3
3
3
3
3
3
3
ACCUMULATION TANKS
Solar
exchanger
65
95
-
-
-
204
78
95
-
-
-
289
87
95
-
-
-
405
94
95
-
-
-
488
108
95
-
-
-
732
127
95
-
-
-
915
162
95
-
-
-
1 449
189
95
-
-
-
1 980
-
95
-
-
-
2 435
-
95
-
-
-
2 915
-
95
-
-
-
3 819
-
95
-
-
-
4 940
64
95
0,9
6
10
198
77
95
1,2
7,9
10
283
84
95
1,5
10
10
388
92
95
1,8 11,9
10
474
105
95
2,4 15,9
10
713
121
95
3
19,8
10
891
161
95
3,6 23,7
10
1 420
188
95
4,2 23,7
10
1 960
-
95
4,2 27,7
10
2 410
-
95
4,2 27,7
10
2 890
-
95
5
33
10
3 779
-
95
6
39,6
10
4 880
Tank
46
60
73
81
109
118
201
235
271
363
475
578
63
83
103
118
157
172
265
296
345
446
568
687
7

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis