Water hardness
Water contains, a variable quantity
of limestone and mineral salts of
which quantities vary according to
geographical locations thus vary-
ing its conductivity values.
Relevant variations of the conduc-
tivity of the water compared to
those prefixed by the factory could
slightly influence the residual hu-
midity of the laundry at the end of
the cycle. Your dryer allows you to
regulate the sensitivity of the dry-
ing sensor based on conductivity
values of the water.

Hints for test institutes

Parameters possible to checked by the Test Institutes:
• Energy consumption (corrected with final humidity)
during the cupboard dry cotton cycle with nominal
load.
• Energy consumption (corrected with final humidity)
during the cupboard dry cotton cycle with half load.
• Final humidity (during cupboard dry cotton, iron dry
cotton and cupboard dry easy care)
1.
Turn the programme selector to any programme.
2.
Press simultaneously the
buttons and hold down for approx. 5 seconds. The current setting is on the
display:
low conductivity <300 micro S/cm
medium conductivity 300-600 micro S/cm
high conductivity >600 micro S/cm
3.
Press the
START/PAUSE button sequentially until you set desired lev-
el.
4.
To memorize setting press simultaneously the the
and
START/PAUSE buttons or turn knob to O
• Condensation efficiency (corrected with final humidity)
All the cycles have to be checked in accordance with EN
61121 (Tumble dryers for household use – Methods for
measuring the performance).
LONG ANTICREASE and
during cupboard dry cotton cycle with nominal and half
load