2.3. CLEANINg THE uPPEr BoDY
1- Separate the upper body (5) from the central body
(1) by twisting it gently anticlockwise.
2- Having separated the upper body (5) from the
central body (1), pull hard on the regulator (9) to
separate it from the connector (7). (FIG B)
3- Remove the silicone valve (8) and the connection
plate (10).
4- All the parts are now separate and ready to be
cleaned/sterilised. Wash with soapy water or sterilise.
To assemble, the process is the same but in reverse.
Bear in mind the following points:
1- Insert the tab on the silicone valve (8) into the
rectangular space in the inner circle of the regulator
(9), pressing gently. (FIG C)
2- When fitting the regulator (9) to the connector (7), it
is easiest to place the inner ridge (9.1) of the regulator
(9) onto the outer tab of the connector (7)
3- Ensure that the suction level mark on the regulator
(9) is positioned between MIN and MAX on the
connector (7).
4- Insert the connection plate (10) into the circular
space in the base of the connector (7)
3. ASSEMBLINg THE BrEAST PuMP AFTEr WASHINg IT
1- Insert the breastshield (4) and
FIg D
press it into the central body (1) with
the aid of the rubber seal (6). This
rubber seal (6) ensures a completely
4. Breastshield
airtight closure.
2- Insert part 11 (rigid) into part
12 (soft silicone), ensuring that it
fits tightly. Bear in mind that the
star-shaped hole in part 11 must
be covered by the movable silicone
membrane in the base of part 12.
This forms the valve (3).
6. Rubber seal
3- Insert the valve (3) into the central
body and screw the bottle (2) on
tightly.
11. Rigid part
12. Soft silicone
part
FIg B
9. Regulator
8. Silicone suction
regulator valve
5. Upper
body
7. Connector
10. Connection plate
FIg C
9. Regulator
9.1. Inner ridge of
the regulator
8. Tab on the
silicone valve
1. Central body
5. Upper
body
3. Valve
2. Bottle
4- Fit the upper body
FIg E
(5) onto the central
body (1). Secure it by
twisting clockwise until
the semicircular mark
on each piece forms a
circle and it clicks into
place. (FIG E)
1. Central body
5- Connect the pump
FIg F
unit (14) to the upper
body (5) with the
tubing (13). (FIG F)
13. Tubing
6- Plug the pump unit
FIg g
(14) into the mains
socket using the power
adapter (15), or remove
the cover of the battery
compartment and insert
four AAA batteries (1.5 V)
as shown.
15. Power adapter
There is a clip (17) on
the cover of the battery
compartment to attach
the pump unit to your
belt. (FIG G)
17. Belt clip
· NoTE:
To ensure the breast pump works properly it is essential that it is assembled correctly. Make sure that all the
parts are fitted together properly. A poor connection can cause air to enter, breaking the vacuum, and if the
pump does not suction the breast, the milk will not flow. In particular, ensure correct assembly of the valve (3),
breastshield (4), membrane (9), tubing (13) and, especially, the upper body (5).
EN - 35